Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T06MH00069
Parcel: 115170130

Review Status: Completed

Review Details: MOBILE HOME

Permit Number - T06MH00069
Review Name: MOBILE HOME
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/19/2006 GERRY KOZIOL WWM REVIEW Approved
05/25/2007 JASON GREEN ENGINEERING REVIEW Denied DATE: May 29, 2007
SUBJECT: 1212 N Riverview Road Manufactured Home Setup- 2nd Engineering Review
TO: ABC Mobile Movers
LOCATION: T14S R13E Sec02, Ward 1
REVIEWERS: Jason Green, CFM
ACTIVITY: T06MH00069 (Site Plan) and T06OT03281 (Floodplain Use Permit)


SUMMARY: Engineering Division of Development Services Department has received and reviewed the revised Site Plan (T06MH00069), Floodplain Use Permit (T06OT03281) and Drainage Statement (Stanley Engineering and Drainage, Inc., 20APR07) for the above referenced property and does not recommend approval of the Site Plan or Floodplain Use Permit at this time.

The subject property is entirely located within a Special Flood Hazard Area (SFHA), Zone AE as shown on the Flood Insurance Rate Map (FIRM), Community- Panel No. 040073-04019C-2226K, effective date February 8, 1999. Federal law requires that a flood insurance policy be obtained as a condition of a federally backed mortgage or loan that is secured by a building located within a SFHA.

The following information is required:


SITE PLAN:

1) TC Sec.26-11.2.2: Provide the 100-year floodplain limits on the revised site plan or a note on the site plan referencing that the entire parcel is within a FEMA SFHA Zone AE.

2) TC Sec.26-8.d: Provide 2 cross sections on the site plan that shows the property lines, fill pad location, manufactured home, and elevation limits of existing ground and future fill pad. Cross sections should be shown going through the north-south and east-west property lines.

3) DS Sec.11-01.2.I: Provide a grading plan and a grading permit application with all associated details for review and approval prior to site plan approval. The limits of the fill pad on the site plan shows that over 50 cubic yards of material are required in order to elevate the proposed manufactured home above the regulatory flood elevation. A grading application is required if fill quantities exceed 50 cubic yards. Provide on the grading plan the cut and fill quantities for permit purposes.

4) DS Sec.11-01.8.1: Provide cross sections on the grading plan through the lot and at all property boundaries to verify that differential grading requirements have been satisfied. Cross sections at all property lines are required to show how the fill pad is used to elevate the manufactured home without encroaching onto adjacent lots.


GENERAL COMMENTS:

Please be advised that since the subject property is located within the SFHA Zone AE floodplain, it will be required that an elevation certificate for the proposed manufactured home be filled out by an Arizona Registered Land Surveyor showing that the bottom of the structural frame or the lowest point of any attached appliances, whichever is lower, is above the regulatory flood elevation (one foot higher than the calculated water surface elevation of the base flood), and returned to our office.

Please provide the revised site plan, a grading plan and application, and all associated details that address the comments provided above.

If you have any questions, or to schedule a meeting I can be reached at 837-4929.


Jason Green, CFM
Senior Engineer Associate
Engineering Division
Development Services
12/08/2006 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Approved