Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T06MH00026
Parcel: 118100310

Review Status: Completed

Review Details: MOBILE HOME

Permit Number - T06MH00026
Review Name: MOBILE HOME
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/28/2006 GERRY KOZIOL WWM REVIEW Passed
08/01/2006 JASON GREEN ENGINEERING REVIEW Approved Lot 11
08/01/2006 JASON GREEN ENGINEERING REVIEW Approved DATE: August 1, 2006
SUBJECT: 2640 S Cottonwood Lane Lot 11- Replacement Manufactured Home
TO: Jennifer Christensen
LOCATION: T14S R13E Sec26, Ward 1
REVIEWERS: Jason Green, CFM
ACTIVITY: T06MH00026 (Site Plan) and T06OT01943 (Floodplain Use Permit)


SUMMARY: Engineering Division of Development Services Department has received and reviewed the submitted Site Plan (T06MH00026) and Floodplain Use Permit (T06OT01943) for the above referenced property and recommends approval of the Site Plan and Floodplain Use Permit at this time.

The subject property is entirely located within a Special Flood Hazard Area (SFHA), Zone AE as shown on the Flood Insurance Rate Map (FIRM), Community- Panel No. 040073-04019C-2228K, effective date February 8, 1999. Federal law requires that a flood insurance policy be obtained as a condition of a federally backed mortgage or loan that is secured by a building located within a SFHA.

The proposed manufactured home replacement is located within an existing manufactured home park, as defined in The Floodplain and Erosion Hazard Management Ordinance, Chapter 26 of the Tucson Code (Ordinance), and is exempt from the requirement of placing the manufactured home replacement on a permanent foundation. However replacement manufactured homes located in the floodplain must be elevated such that the bottom of the structural frame or the lowest point of any attached appliances, whichever is lower, is above the regulatory flood elevation (one foot higher than the calculated water surface elevation of the base flood). The manufactured home must be securely anchored. Certification by a state-registered professional civil engineer that the installation of the manufactured home meets all the requirements of Section 26-9 of the Ordinance is required. Certification of elevation must be prepared by a state registered land surveyor.

For purposes of this permit the following flood elevations shall be used:
Base Flood Elevation (BFE) = 2381.0 feet NGVD 1929
Regulatory Flood Elevation (RFE) = 2382.0 feet NGVD 1929

Bottom of the structural frame of the manufactured home and lowest point of any attached appliances to be at or above the Regulatory Flood Elevation (RFE).

Please be advised that since the subject property is located within the SFHA Zone AE floodplain, it will be required that an elevation certificate for the proposed manufactured home replacement be filled out by an Arizona Registered Land Surveyor showing that the bottom of the structural frame or the lowest point of any attached appliances, whichever is lower, is above the regulatory flood elevation (one foot higher than the calculated water surface elevation of the base flood), and returned to our office.


If you have any questions, I can be reached at 791-5550, extension 1189.



Jason Green, CFM
Senior Engineer Associate
Engineering Division
Development Services
08/02/2006 DAVE WITT BUILDING-RESIDENTIAL REVIEW Approved