Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T06MH00010
Parcel: 118100270

Review Status: Completed

Review Details: MOBILE HOME

Permit Number - T06MH00010
Review Name: MOBILE HOME
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/22/2006 SREEVES1 WWM REVIEW Approved
05/25/2006 JASON GREEN ENGINEERING REVIEW Denied DATE: May 26, 2006
SUBJECT: 2640 S Cottonwood Ln- Replacement Manufactured Home
TO: ABC Movers
LOCATION: T13S R13E Sec33, Ward 1
REVIEWERS: Jason Green, CFM
ACTIVITY: T06MH00010 (Site Plan) and T06OT01364 (Floodplain Use Permit)


SUMMARY: Engineering Division of Development Services Department has received and reviewed the Site Plan (T06CM01123) and Floodplain Use Permit (T06OT00831) for the above referenced property and does not recommend approval of the Site Plan or Floodplain Use Permit at this time.

The subject property is entirely located within a Special Flood Hazard Area (SFHA), Zone AE as shown on the Flood Insurance Rate Map (FIRM), Community- Panel No. 040073-04019C-2228K, effective date February 8, 1999. Federal law requires that a flood insurance policy be obtained as a condition of a federally backed mortgage or loan that is secured by a building located within a SFHA.

The proposed manufactured home replacement is located within an existing manufactured home park, as defined in The Floodplain and Erosion Hazard Management Ordinance, Chapter 26 of the Tucson Code (Ordinance), and is exempt from the requirement of placing the manufactured home replacement on a permanent foundation. However replacement manufactured homes located in the floodplain must be elevated such that the bottom of the structural frame or the lowest point of any attached appliances, whichever is lower, is above the regulatory flood elevation (one foot higher than the calculated water surface elevation of the base flood). The manufactured home must be securely anchored. Certification by a state-registered professional civil engineer that the installation of the manufactured home meets all the requirements of Section 26-9 of the Ordinance is required. Certification of elevation must be prepared by a state registered land surveyor.


SITE PLAN:

1) Revise the submitted detail and the site plan to show that the bottom of the structural frame or the lowest point of any attached appliances, whichever is lower, is at or above the regulatory flood elevation (2386.5 feet NGVD 1929).

2) Revise the site plan to show that all service equipment, such as air conditioning, evaporating coolers, electrical and heating equipment servicing the manufactured home are elevated at or above the regulatory flood elevation (2386.5 feet NGVD 1929).


GENERAL COMMENTS:

Please be advised that since the subject property is located within the SFHA Zone AE floodplain, it will be required that an elevation certificate for the proposed manufactured home replacement be filled out by an Arizona Registered Land Surveyor showing that the bottom of the structural frame or the lowest point of any attached appliances, whichever is lower, is above the regulatory flood elevation (one foot higher than the calculated water surface elevation of the base flood), and returned to our office.

Please provide a revised detail on the site plan that address the comments provided above.

If you have any questions, I can be reached at 791-5550, extension 1189.



Jason Green, CFM
Senior Engineer Associate
Engineering Division
Development Services

Final Status

Task End Date Reviewer's Name Type of Review Description
06/06/2006 ADRIANNE OLIVO APPROVAL SHELF Completed
06/06/2006 ADRIANNE OLIVO OUT TO CUSTOMER Completed
06/06/2006 ADRIANNE OLIVO REJECT SHELF Completed