Permit Review Detail
Review Status: Completed
Review Details: POST 3RD PARTY REVIEW
Permit Number - T06CM06554
Review Name: POST 3RD PARTY REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/22/2007 | GERRY KOZIOL | WWM | REVIEW | Passed | |
| 03/22/2007 | DAVE MANN | FIRE | REVIEW | Approved | |
| 03/26/2007 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 04/04/2007 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: Taylor Tack & Feed T06CM06554 Building Plan (1st Review) TRANSMITTAL DATE: April 4, 2007 1. The building plan has been reviewed by Zoning Review Section but cannot approve the plan at this time. 2. Zoning could not verify that the building plan was in compliance with the approved site plan. Please submit two copies of the approved and stamped site, landscape, and NPPO plans with the next building plan submittal. 3. Zoning will re-review the building plan on the next submittal to insure compliance with the approved and stamped site plan. Additional comments may be forthcoming. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 C:\planning\building\t06cm06554.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Approved and stamped site plan and additional requested documents |
| 05/09/2007 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: ASI DATE: May 9, 2007 Architects studio, Inc. 6011 E. Grant Road Tucson, Arizona 85712 SUBJECT: Taylor Tack and Feed, 9535 E. Golf Links Road Site plan T06CM06362 (Second Review) T14S, R15E, Section 23 RESUBMITTAL REQUIRED: Site Plan and Drainage Report. The Site Plan (SP) and Drainage Report (ER) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Site Plan: 1. Please include a response letter to the comments along with the corrected copies of the SP. All comments were not addressed in the response letter. Submit a detailed response letter with the next submittal. 2. The feed store (4000 sf ) building is encroaching into the flowage easement. This may impede stormwater flow and the building shall be removed from encroaching into the 16' drainage easement. This easement is still be used, explain how it can be abandoned? 3. Show all points of egress and ingress including locations and width of driveways and parking area access lanes (P.A.A.L.) per D.S. 2-02.2.1.11. Per previous comment. 4. Please label all vehicular, bicycle, pedestrian, and handicapped circulation clearly identified per D.S. 2-02.2.1.12. Per previous comment. 5. Fully dimensioned loading space(s) and maneuvering area(s) per D.S. 2-02.2.1.14. Per previous comment. 6. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0. The refuse enclosure entrance is not located on the projects property, explain why? Per previous comment. 7. Add note: "Depress all landscaped areas 6" maximum for water harvesting". Provide curb openings at each landcsaped area and grade to accept water for harvesting. Drainage Report: 1. Please include a response letter to the comments along with the corrected copies of the DR. 2. Demonstrate that any unattenuated 100-yr. peak discharge from the existing culvert system is able to be conveyed through the site without adverse impact to the existing or proposed main structures per D.S. DS Sec.2-02.2.1.A.16 and 22. 3. All weather access must be demonstrated per S.M.D.D.F.M. Chapter 11.2.0.1. 4. The feed store (4000 sf ) building is encroaching into the flowage easement. This may impede stormwater flow and the building shall be removed from encroaching into the 16' drainage easement. This easement is still be used, explain how it can be abandoned? Per previous comment. 5. Show the project address or administration address of the project must be shown on the cover sheet of the DR., not the owners or the property. Per previous comment. If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4932 office (520) 879-8010 fax C:/-9535 E. Golf Links Road Site |
| 06/14/2007 | SUE REEVES | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/09/2007 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 07/09/2007 | SUE REEVES | REJECT SHELF | Completed |