Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T06CM06535
Parcel: 12308002B

Review Status: Completed

Review Details: SITE

Permit Number - T06CM06535
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/02/2007 STEVE SHIELDS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Farmers Insurance Remodel
T06CM06535
Site Plan (1st Review)

TRANSMITTAL DATE: January 3, 2007

COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for the area effected by the proposed entry porch and handicapped ramps.

2. Based on the provided last approved site plan a required loading zone was removed from the site. Provide a 12'x35' loading zone on site.

3. The proposed handicapped ramp and railings located at the northeast corner of the existing building encroach into the existing 24 foot entrance PAAL. Revise plan to maintain a minimum 24' PAAL.

4. An over the counter review may be scheduled once the above comments have been addressed. Call or email to schedule an appointment.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 791-5608 ext. 1180.

C:\planning\site\t06cm06535.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents
01/03/2007 STEVE SHIELDS ZONING HC SITE REVIEW Denied See zoning comments
01/03/2007 SSHIELD1 ADA REVIEW Passed
01/10/2007 JOE LINVILLE LANDSCAPE REVIEW Denied This site plans adds a new parking space adjacent to Country Club Road. Expansions of parking are subject to LUC 3.7.2.4 which would require a street landscape border. This parking mofification does not appear viable based on the landscape requirements.
01/10/2007 JOE LINVILLE NPPO REVIEW Denied Submit a native plant preservation plan or Application for exception. LUC 3.8
02/06/2007 SUZANNE BOHNET ENGINEERING REVIEW Denied DATE: February 7, 2007
FROM: Suzanne Bohnet, CFM
Engineering Division

SUBJECT: 1131 N. Country Club Rd.
Farmer's Insurance Co.
Site Plan T06CM06535 (First Review)

RESUBMITTAL REQUIRED: Site Plan.

The Site Plan cannot be approved as submitted. Please include a response letter to the comments below along with the corrected copies of the Site Plan with your next submittal.

Site Plan:
1. Upon approval, this Site Plan will be the "last-approved" Site Plan and, as such, requires completion of content and specifications per the Development Standards (DS) Chapter 2-02.
2. Provide a Site Plan drawn at a standard engineering scale no larger than 1" = 60' (DS 2-02.2.1.A).
3. Provide the lot bearings and the Basis of Bearings (DS 2-02.2.1.A.5).
4. Provide the existing sight visibility triangles (SVT) for the drive at Country Club Rd (DS 2-02.2.1.A.10).
5. Provide a fully dimensioned loading space and maneuvering area (DS 2-02.2.1.A.14).
6. Provide existing drainage flow arrows with supporting contour lines or spot elevations. Provide the Basis of Elevation used (DS 2-02.2.1.A.16 and 2-02.2.1.A.23).
7. Provide a dimensioned right-of-way, labeling Country Club Rd. as a Major Street & Route (MS&R) (DS 2-02.2.1.A.19). Include the future width of the right-of-way, including the taper design for the intersection of Country Club Rd. and Speedway Blvd., however it is not necessary to provide and/or label the future curb location, future sidewalks or future SVT.
8. Provide the dimensions from the street monument line to existing curbs and sidewalks (DS 2-02.2.1.A.21).
9. Provide the location of the refuse container (DS 2-02.2.1.A.32).

Please do not hesitate to contact me with any questions.

Thank you,
Suzanne Bohnet, CFM
Engineering Associate
(520) 791-5550 x1188 office
Suzanne.Bohnet@tucsonaz.gov
12/29/2006 MARTIN BROWN FIRE REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
04/02/2007 FSANCHE1 OUT TO CUSTOMER Completed
04/02/2007 SUE REEVES REJECT SHELF Completed