Permit Number: T06CM06362
Parcel: 13608477H

Review Status: Completed

Review Details: RESUBMITTAL - SITE ALL

Permit Number - T06CM06362
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/28/2007 DAVE MANN FIRE REVIEW Approved
03/13/2007 ANDREW CONNOR NPPO REVIEW Passed Meets NPPO Requirements.
03/13/2007 ANDREW CONNOR LANDSCAPE REVIEW Passed Meets NPPO Requirements.
03/13/2007 STEVE SHIELDS ZONING HC SITE REVIEW Approved
03/13/2007 STEVE SHIELDS ZONING REVIEW Approved DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: Taylor Tack & Feed
T06CM06362
Site Plan (2nd Review)

TRANSMITTAL DATE: March 13, 2007

COMMENTS: Please resubmit revised drawings along with a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This site plan was reviewed for full code compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC).

2. Provide the abandonment documentation. The proposed 4000 sq. ft. retail building is shown being built over a 16' flowage easement. Provide documentation, which either allows construction of a structure in this easement, or abandons the easement. Additional comments may be forth coming.

3. For your information only, the detectable warning devices shown at the south end of the handicapped access aisle are not required at that location. D.S. 2-02.A.2.1.12 Detectable warnings (truncated domes) will be required at all curb access ramps. ICC/ANSI A117.1-2003 Sec. 406.13

4. This comment has not been addressed. "4 CLASS 1 PROVIDED" is still shown on the plan. Zoning acknowledges that 4 Class 2 bicycle parking spaces have been provided. Revise the bicycle parking calculation to reflect what has been provided. D.S. 2-02.2.2.4 the bicycle parking calculation is incorrect. The calculation shows "4 CLASS 1 PROVIDED" all information/details on the plan specify Class 2. Per LUC Sec. 3.3.7.8 Any use providing less than fifty (50) motor vehicle parking spaces my substitute Class 2 for Class 1 spaces. Revised the bicycle parking calculation.

5. Zoning acknowledges the copy of the "AMENDMENT OF WAIVER OF ENFORCEMENT OF DECLARATION OF CONDTIONS AND RESTRICTIONS AND DECLARATION OF COVENANTS RUNNING WITH THE LAND. Provide recordation information, docket and page for the amendment.

6. Zoning will provide an over the counter review once the above comments are addressed. Please call or email to set an appointment for this review.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 791-5608 ext. 1180.

C:\planning\site\t06cm06362-2nd.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents
05/04/2007 PAUL MACHADO ENGINEERING REVIEW Denied To: ASI DATE: May 9, 2007
Architects studio, Inc. FROM: Paul Machado
6011 E. Grant Road Engineering Division
Tucson, Arizona 85712

SUBJECT: Taylor Tack and Feed, 9535 E. Golf Links Road
Site plan T06CM06362 (Second Review)
T14S, R15E, Section 23

RESUBMITTAL REQUIRED: Site Plan and Drainage Report.

The Site Plan (SP) and Drainage Report (ER) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Site Plan:

1. Please include a response letter to the comments along with the corrected copies of the SP. All comments were not addressed in the response letter. Submit a detailed response letter with the next submittal.
2. The feed store (4000 sf ) building is encroaching into the flowage easement. This may impede stormwater flow and the building shall be removed from encroaching into the 16' drainage easement. This easement is still be used, explain how it can be abandoned?
3. Show all points of egress and ingress including locations and width of driveways and parking area access lanes (P.A.A.L.) per D.S. 2-02.2.1.11. Per previous comment.
4. Please label all vehicular, bicycle, pedestrian, and handicapped circulation clearly identified per D.S. 2-02.2.1.12. Per previous comment.
5. Fully dimensioned loading space(s) and maneuvering area(s) per D.S. 2-02.2.1.14. Per previous comment.
6. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0. The refuse enclosure entrance is not located on the projects property, explain why? Per previous comment.
7. Add note: "Depress all landscaped areas 6" maximum for water harvesting". Provide curb openings at each landcsaped area and grade to accept water for harvesting.

Drainage Report:
1. Please include a response letter to the comments along with the corrected copies of the DR.
2. Demonstrate that any unattenuated 100-yr. peak discharge from the existing culvert system is able to be conveyed through the site without adverse impact to the existing or proposed main structures per D.S. DS Sec.2-02.2.1.A.16 and 22.
3. All weather access must be demonstrated per S.M.D.D.F.M. Chapter 11.2.0.1.
4. The feed store (4000 sf ) building is encroaching into the flowage easement. This may impede stormwater flow and the building shall be removed from encroaching into the 16' drainage easement. This easement is still be used, explain how it can be abandoned?
5. Show the project address or administration address of the project must be shown on the cover sheet of the DR., not the owners or the propertyPer previous comment.

If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4932 office
(520) 879-8010 fax
C:/-9535 E. Golf Links Road Site

Final Status

Task End Date Reviewer's Name Type of Review Description
07/09/2007 DELMA ROBEY OUT TO CUSTOMER Completed
07/09/2007 DELMA ROBEY REJECT SHELF Completed