Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING-WALKTHRU
Permit Number - T06CM06337
Review Name: RESIDENTIAL BLDG/ZONING-WALKTHRU
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/20/2007 | CAGUILA1 | NPPO | REVIEW | Needs Review | |
| 02/20/2007 | CAGUILA1 | ENGINEERING | REVIEW | Needs Review | |
| 02/20/2007 | CAGUILA1 | BUILDING-RESIDENTIAL | REVIEW | Needs Review | |
| 12/19/2006 | TERRY STEVENS | ZONING | REVIEW | Denied | DSD Zoning Review Transmittal FROM: Terry Stevens Lead Planner PROJECT: (Activity Number) T06CM06337 (Address) 3504 E Belmar Av (Use) SFR: Additions: carport, dining room, front porch, bedroom TRANSMITTAL DATE: 12-19-06 COMMENTS: 1. The proposed site is in a R-2 zone. The use is Family Dwelling with Development Designator "I" subject to LUC Sec. 3.5.7.1.F. Development Designator "I" per LUC Sec. 3.2.3.1.B has a perimeter yard indicator of AA. The required perimeter yard setbacks per LUC Sec. 3.2.6.4 for a perimeter yard indicator AA with adjacent zoning of R-2 is 6' or 2/3 the height of the structure which ever is greater. The required street perimeter yard setback per LUC Sec. 3.2.6.5.A is 20' or 11/2 times the height of the structure. 2. The existing detached accessory storage building located in the southwest corner of the property, per the above listed codes, requires a minimum of 6' setback from the south and the west property line. Owner proposes a setback of 1'-7" from the south property line and 1'-7" from the west property line. 3. The existing detached accessory ramada located near the southwest corner of the property, per the above listed codes, requires a minimum 6' setback from the south property line. Owner proposes a 2'-0" setback from the south property line. 4. The proposed dining room addition located near the southeast corner of the property, per the above listed codes, requires a minimum setback 0f 6'-0" from the south property line. Owner proposes a setback of 5'-0" from the south property line. 5. The proposed porch (covered walkway) located in the street perimeter yard setback at the east property line requires a minimum setback of 20'-0" from the east property line. Owner proposes a 0'-0" setback from the east property line. 6. The proposed carport located along the north property line requires a minimum setback from the north property line of 7'-7". Owner proposes a 1'-0" setback from the north property line. 7. Based on the information provided on this site plan a Design Development Option (DDO) is required for the setbacks listed in item #2, #3, #4, #5 and #6. If you have any questions about this transmittal, please call Terry stevens, (520) 791-5550 ext. 2000. |