Permit Number - T06CM06319
Review Name: RESUBMITTAL - SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/17/2007 | HEATHER THRALL | ZONING | REVIEW | Denied | TO: Development Services Department Plans Coordination Office FROM: Heather Thrall Senior Planner PROJECT: T06CM06319 401 S. Euclid Avenue (possibly 201 S. Euclid) Commercial site plan, 3rd Review, New offices and commercial storage TRANSMITTAL DATE: August 17, 2007 COMMENTS: Please contact me for a counter appointment when the following easement and cross access issues are corrected in the documents being drafted. 1. Per DS 2-02.2.1.14, with regards to loading zones: (contact me once agreement amended) A) The Zoning Administrator has determined the loading zone for building 8 may be located on the adjacent lot near existing buildings 2 and 3, providing the cross access agreement is amended to include loading zone use. 2. Per DS 2-02.2.1.20, I see easements noted on sheet A.1.2. (contact me once easement is abandoned) Please ensure that all easements, even those to be abandoned, are graphically depicted on the plan, with their docket, page of recordation and type. For those easements that are to be abandoned, please provide additional note that they are abandoned, and list their docket and page of recordation. 3. Please note that further review comments may be forthcoming, depending upon the responses provided. Should you have any questions on this review, I can be reached via email at Heather.Thrall@tucsonaz.gov or at 520-791-5550x1156. HCT C:\planning\site\DSD\T06CM06319 401 S. euclid 3.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents |
| 08/17/2007 | HEATHER THRALL | ZONING HC SITE | REVIEW | Approved | |
| 08/28/2007 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 09/07/2007 | JASON GREEN | ENGINEERING | REVIEW | Approved | DATE: September 7, 2007 SUBJECT: Central City Business Park- 3rd Engineering Review TO: Michael Schooler LOCATION: 401 S Euclid, T14S R14E Sec18 Ward 5 REVIEWERS: Jason Green, CFM ACTIVITY: T06CM06319 SUMMARY: Engineering Division of Development Services Department has received and reviewed the revised site plan (T06CM06319), grading plan (T07BU00958), drainage report (Castro Engineering, Corp, 03APR07), and Stormwater Prevention Pollution Plan, for the above referenced property. Engineering Division recommends approval of the site plan at this time. ยง If any changes occur to the site plan due to other Development Services Departments comments Engineering Division will be required to re-review the submittal and re-stamp the plans approved. If you have any questions, or to schedule an appointment, I can be reached at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division Development Services |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/10/2007 | SUE REEVES | OUT TO CUSTOMER | Completed |