Permit Number: T06CM06303
Parcel: 13325183B

Review Status: Completed

Review Details: RESUBMITTAL - SITE ALL

Permit Number - T06CM06303
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/15/2007 DAVE MANN FIRE REVIEW Approved
04/18/2007 TERRY STEVENS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: T06CM06303
850 E. Speedway Blvd.
Retail Site Plan

TRANSMITTAL: 04/19/07

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. DS 2-02.2.1.9 On detail 5 of SP-1 clearly indicate the location of the bicycle racks on the overhead view. Use a heavier line weigh for the overhead view. Clearly indicate the width of the bicycle parking area and the space between racks. See DS 2-09.5.1 and Figure 9 for bicycle parking space dimensions.

2. DS 2-02.2.1.12 The pedestrian refuge areas have been clearly indicated. Provide the location and widths of all sidewalks along the north, south and west sides of the proposed building. If the pedestrian refuge areas indicated are also the width of the sidewalks clearly indicate such.

On detail 8 of SP-1 remove the note stating "top of sign +5'-6". Per City of Tucson standards the minimum required distance from grade to the bottom of the handicap sign is seven (7) feet.

3. DS 2-02.2.1.31 The proposed use for this project should be listed as "General Merchandise Sales "28" subject to: 3.5.9.2.c". Revise Code Review note.

4. DS 2-02.2.2.A.3 The lot coverage percentage provided is not required. Remove note.

5. On detail 6 of SP-1, remove the handicap parking space, access aisle and handicap ramp on the right side of the detail. This portion of the detail is not used on this site and the handicap ramp is shown incorrect.

6. The above changes are minor in nature and can be reviewed over the counter by setting an appointment with me.

If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961
04/19/2007 TERRY STEVENS ZONING HC SITE REVIEW Approved
04/23/2007 CAGUILA1 LANDSCAPE REVIEW Needs Review
04/23/2007 CAGUILA1 PLUMBING-COMMERCIAL REVIEW Needs Review
04/23/2007 CAGUILA1 ENGINEERING REVIEW Needs Review
04/23/2007 CAGUILA1 NPPO REVIEW Needs Review