Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T06CM06296
Parcel: 12511197B

Address:
832 N RICHEY BL

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T06CM06296
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/26/2007 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS
Activity # T06CM06296
Date: 3/12/07
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken.

SCOPE OF REVIEW:
The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2003 International Residential Code, 2003 International Energy Conservation Code, and Arizona State amendments to the 2003 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:
All corrections and revisions shall be made on original tracings or finished reproducible set. Return this set and a copy along with a set of the first submission. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets.

All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration.

SITE PLAN:
1. Indicate the location of gas, water, electric and sewer or septic line on the property, from property line to building. Provide the location of both sets of utility meters (show location of any abandoned meters).

FOUNDATION PLANS:
1. Show or note a 6" minimum separation of untreated exterior posts above finished grade along with a 1" space above the floor, R319.1.4 (post base specified does not provide 1" standoff).
2. Provide dimension from end of building to post footings (east to west please).
3. Provide size and detail for interior footing at new 4x4 column per note 1/A1.1 (it is no longer "existing" if it is replaced).

STRUCTURAL PLANS:
1. Provide complete roof framing plan and details for existing roof to include:
· Rafter dimensions, spac ing, and spans
· Existing roofing materials
· Show wood beams with 1/2" end clearances from masonry, R319.1 (4).
(Justify interior beam size)
(Detail beam connections to existing rafters and masonry wall)

ELECTRICAL PLANS:
1. Verify location of abandoned or modified panels (with details).
2. Verify range/oven wire size and overcurrent device.

If you have any questions please contact
Clayton Trevillyan
791-5550 ext. 1113

Final Status

Task End Date Reviewer's Name Type of Review Description
03/27/2007 CINDY AGUILAR OUT TO CUSTOMER Completed
03/27/2007 CINDY AGUILAR REJECT SHELF Completed