Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T06CM06267
Parcel: 12009052A

Address:
4415 S 6TH AV

Review Status: Completed

Review Details: REVISION - - 2ND

Permit Number - T06CM06267
Review Name: REVISION - - 2ND
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/15/2008 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Denied 1. PLEASE SCHEDULE A MEETING WITH THE DESIGNER OF RECORD TO DISCUSS THE SAME FIVE REVIEW COMMENTS THAT HAVE APPEARED OVER THE LAST FEW REVIEWS. NO PROGRESS HAS BEEN MADE ON ANY OF THE FIVE PREVIOUS COMMENTS.
07/24/2008 LINDA BUCZYNSKI ELECTRICAL-COMMERCIAL REVIEW Denied TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL.

PLEASE CALL AT 520.837.4907 OR EMAIL AT Linda.Buczynski@tucsonaz.gov
IF YOU CARE TO DISCUSS.

1. Water Heater is 240V, on Sheet C-1 and cut sheet, 208V on Electrical Power Plan. On the cut sheet the 208V WH is a different model. Coordinate among disciplines and clarify.
2. Provide location on plans for Outside Cold Box and Walk-In Cooler. PREVIOUS COMMENT.
3. EC-1 cancelled by Owner according to load calculations. However, this equipment is still called for on Sheet MP-1 and on the electrical line diagram. Please clarify.
4. Sheet MP-1 Equipment Schedule calls for EC-1, EF-1, CU-1, and C-1. Provide electrical circuits, and use the same equipment designations. PREVIOUS COMMENT. Indicate panel and circuit number for C-1.
5. Provide load calculations for Panel L. Separate load calculations for the electrical service. Lighting at 125%, and include exterior fixture. Add 25% for largest motor. PREVIOUS COMMENT. Load calculations performed on a 3-phase basis. Panel and other electrical loads set up on a single-phase basis. Clarify.
6. 20-Receptacles would account for a minimum of 3600VA, not 2880.
7. Panel L is set up as a single phase panel. At 120/208V, per the schedule itself, this would be a three phase panel. PREVIOUS COMMENT.
8. Add the following to Load Calculations: Outside cold Box, Walk-In Fan, Water Heater, Walk-In Cooler. PREVIOUS COMMENT.
9. Revise the font size used on the drawings to a minimum of 1/8-inch (all upper case). Reference Section 106.1.1, IBC 2006. PREVIOUS COMMENT.
10. Document location of TEP transformer on scaled drawing.
11. In the fault calculations 3/0 is used on the line side of the meter. On the line diagram, this is 600 KCMIL. Clarify.
12. On the line diagram, there is a circuit breaker inside of the meter enclosure. Clarify.
13. Fault calculations will be reviewed after 3-phase vs. single-phase service is clarified.
14. Date your revisions according to the Rules and Regulations of the Arizona State board of Technical Registration. As the electrical plans stand, they were previously reviewed 7/1/08, then sealed 6/19/08 and turned back in for review 7/14/08. This is a faulty chronology, for the revision triangle is not associated with any date.

Final Status

Task End Date Reviewer's Name Type of Review Description
07/28/2008 CINDY AGUILAR OUT TO CUSTOMER Completed
07/28/2008 SUE REEVES REJECT SHELF Completed