Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T06CM06267
Parcel: 12009052A

Address:
4415 S 6TH AV

Review Status: Completed

Review Details: REVISION - - 2ND

Permit Number - T06CM06267
Review Name: REVISION - - 2ND
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/24/2008 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Denied 1. SHOW ACCESSIBILITY ROUTE FROM REAR EXIT AROUND BUILDING TO FRONT ENTRANCE. PREVIOUS COMMENT.
2. REMOVE WATER HEATER DETAIL. PREVIOUS COMMENT.
3. DOOR AND RAMP TO DELIVERIES ROOM ARE IN THE WRONG LOCATION. REVISE. PREVIOUS COMMENT.
4. CHANGE DRAWINGS TO INDICATE DRINKING FOUNTAIN/SERVICE SINK LOCATIONS. PREVIOUS COMMENT.
5. DIMENSION VERTICAL GRAB BAR IN RESTROOM. PREVIOUS COMMENT.
6. REMOVE MECHANICAL UNITS ON ROOF FROM ALL PLANS. PREVIOUS COMMENT.
7. PROVIDE NEW SEALS/SIGNATURES FOR ALL REVISED SHEETS. PREVIOUS COMMENT.
8. PROVIDE RESPONSE LETTER TO BUILDING REVIEW COMMENTS.
04/25/2008 LINDA BUCZYNSKI ELECTRICAL-COMMERCIAL REVIEW Denied TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL.

PLEASE CALL AT 520.837.4907 OR EMAIL AT Linda.Buczynski@tucsonaz.gov
IF YOU CARE TO DISCUSS.

1. Provide documentation that Water Heater is cord-connected, or provide local disconnect.
2. Water Heater is 240V, but on Electrical Power Plan L-28 is a 120V outlet.
3. PROVIDE COMPLETE SET OF PREVIOUSLY APPROVED PLANS. This comment was made on the review of 2/13/08. As best as we can determine an evaporative cooler was crossed out on the current submittal, but it was there on the approved plans. Current submittal is on Revision 3 on Sheet E-1, but this is also the last dated Revision on our archived approved plans. Date and nature of revision to plans has to be indicated. Reference Arizona State Board of Technical Registration R4-30-304.
4. Same as comment above for change of poles on Water Heater overcurrent protective device on panel schedule.
5. Same as comments above for Electrical Load Calculation.
6. Add the following to Load Calculations: Beverage Cases, Ice Machine, Walk-In Fan, receptacle loads.
7. Division by 1.74 not valid. This is single phase, not three phase.
8. Study NEC Article 220, then revisit load calculations.
9. Arizona State Board of Technical Registration Statutes 32-143 Exceptions, states:
A registrant under this chapter may engage in practice in another category regulated pursuant to this chapter only to the extent that the person is qualified and to the extent that the work may be necessary and incidental to the work of the registrant's profession on a specific project.
Based upon the plans and in accordance with the State Board of Technical Registration Rules, this plan should be designed and sealed by an Arizona Registered Professional Electrical Engineer.

Final Status

Task End Date Reviewer's Name Type of Review Description
05/22/2008 DELMA ROBEY OUT TO CUSTOMER Completed
05/22/2008 SHANAE POWELL REJECT SHELF Completed