Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T06CM06265
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
02/01/2007 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. The architectural details showing the wall connection requirements for the water heater installation (Detail 1/P3.0) do not appear to be adequate to support the specified water heater. The wall is an interior partition constructed of 25-gage metal studs and gypsum board with no internal blocking to accept the bolts and the holes in the 6"x6" plates are too small for the specified lag bolts. Resolve the physical incongruities and provide calculations to justify the methods of support. Reference Section 103.2.3, UPC 2003. 2. All storage-type water heaters located in a water system having a check valve or a backflow preventer must be provided with a means to control water expansion. Please show how this is to be accomplished. Reference Section 608.3, UPC 2003 with local amendments. |
02/05/2007 | CHRISTY FOREMAN | BUILDING-COMMERCIAL | REVIEW | Denied | CITY OF TUCSON DEVELOPMENT SERVICES STRUCTURAL REVIEW COMMENTS DATE: 2/05/07 ACTIVITY NUMBER: T06CM06265 PROJECT NAME: SLEEP AMERICA PROJECT ADDRESS: 9660 E. 22ND ST ARCHITECT / ENGINEER: PHOENIX DESIGN ONE PROJECT REVIEWER: CHRISTY FOREMAN TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL. PLEASE CALL AT 791-5550 X1108 OR EMAIL AT CHRISTY.FOREMA1@TUCSONAZ.GOV IF YOU CARE TO DISCUSS. 1) Display Arch wall - please justify per section 1621.1.2 IBC 2003. Overall height is 7'-0" therefore provide lateral bracing or provide structural calculations justifying seismic load does not exceed 5 psf required in section 1607.13. |
02/07/2007 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Approved |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
02/21/2007 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
02/21/2007 | SUE REEVES | REJECT SHELF | Completed |