Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T06CM06265
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/08/2007 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Denied | TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL. PLEASE CALL AT 791-5550 X1106 OR EMAIL AT Linda.Buczynski@tucsonaz.gov IF YOU CARE TO DISCUSS. 1. Circuit A5-10 is designated on the Lighting Plan, but is listed as a spare on the panel schedule. Please clarify. 2. Please note that track lighting shall be counted at 75 VA/LF for feeder calculations. Reference NEC 220.12 (B). (36) (75) = 2700 VA on A5-8. Additional 25% if these fixtures are anticipated to operate continuously. 3. Account for continuous load and largest motor in panel/feeder calculations. If these have already been factored in, clarify such on the plans. |
| 01/12/2007 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 12/14/2006 | BETSY COTTLE | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 12/15/2006 | DAVE MANN | FIRE | REVIEW | Approved | |
| 12/18/2006 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Provide the architectural details showing the wall connection requirements for the water heater installation (Note 6, Detail 1/P3.0). Reference Section 103.2.3, UPC 2003. |
| 12/18/2006 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 12/18/2006 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
| 12/22/2006 | CHRISTY FOREMAN | BUILDING-COMMERCIAL | REVIEW | Denied | CITY OF TUCSON DEVELOPMENT SERVICES STRUCTURAL REVIEW COMMENTS DATE: 12/22/06 ACTIVITY NUMBER: T06CM06265 PROJECT NAME: SLEEP AMERICA PROJECT ADDRESS: 9660 E. 22ND ST ARCHITECT / ENGINEER: PHOENIX DESIGN ONE PROJECT REVIEWER: CHRISTY FOREMAN TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL. PLEASE CALL AT 791-5550 X1108 OR EMAIL AT CHRISTY.FOREMA1@TUCSONAZ.GOV IF YOU CARE TO DISCUSS. 1) Minimum text size shall be 1/8" = 1'-0" on all drawings. 2) Display Arch wall - please justify per section 1621.1.2 IBC 2003. 3) Sales / service counter clarify location of millwork that complies with section 904.3 ANSI A117.1 2003. 4) Dimension north storage room wall. 5) Justify occupant load for retail space and storage space. |