Permit Number: T06CM06162
Parcel: 13621004E

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T06CM06162
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/20/2007 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Approved
11/21/2007 RONALD BROWN BUILDING-COMMERCIAL REVIEW Denied 1. PROVIDE COMPLETED CITY OF TUCSON CODE REVIEW CHECK LIST. REFERENCE WEB SITE, www.tucsonaz.gov/index.php, CLICK ON BUILDING AND SIGN PERMITS, SELECT SUBMITTAL REQUIREMENTS AND LASTLY SELECT CODE REVIEW CHECK LIST
2. SHOW AND DEFINE ALL ACCESSIBILITY ROUTES TO SITE AND ALL BUILDING ENTRANCES FROM STREET AND FROM H/C PARKING SPACES. SHOW ALL LONGITUDAL AND LATERAL SLOPES THROUGH ALL ROUTES
3. USE ANSI 117.1 FOR ACCESSIBLE CODE. ALL TOILETS MUST MET THESE REQUIREMENTS, REVISE DRAWINGS ACCORDINGLY. DIMENSION ALL CLEARANCES


4. NEED EXISTING/DEMO SITE PLAN
5. ARCHITECTURAL SITE PLAN SHEET A000 LACKS SUFFICIENT DETAIL TO DEFINE NEW CONSTRUCTION SITE WORK TO WHAT IS EXISTING TO REMAIN AND DIMENSIONS.
6. TABLE 601 DOES NOT PERMIT SPRINKLER SUBSTITUTION FOR 1 HOUR RATING OF EXTERIOR WALLS. NEED TO PROVIDE ALL DETAILING FOR I HOUR EXTERIOR WALL AND COLUMN PROTECTION. MAYBE YOU MIGHT WANT TO GO TO TYPE IIB AND PROVIDE FIRE SEPARATION BETWEEN OCCUPANCIES.
7. SANCTUARY, PLATFORM, CHOIR LOFT, BAPISTY, AND TOILETS 116 AND 117 ARE NOT ACCESSIBLE. REFERENCE ANSI 117.1 AND IBC 2006 SECTION
8. ALL TOILETS MUST BE ACCESSIBLE INCLUDING TOILET 104
9. NEED STRUCTUTAL CALCULATIONS FOR INTERIOR PLATFORM AND ACCESSORY LEVELS.

Final Status

Task End Date Reviewer's Name Type of Review Description
12/20/2007 VFLORES1 OUT TO CUSTOMER Completed
12/20/2007 VFLORES1 REJECT SHELF Completed