Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T06CM06092
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/05/2006 | LEERAY HANLY | BUILDING-COMMERCIAL | REVIEW | Denied | 1) PROVIDE CODE ANALYSIS DATA SHEET FOR BUILDING AND T.I. 2) PROVIDE STRUCTURAL DETAILS FOR WALL FRAMING, CABINET BACKING, ETC. 3) INDICATE WALL FINISH OF HARD, NON-ABSORBANT SURFACE PER SECTION 1210.2 OF IBC. 4) CLARIFY HOW 2'10" DOOR TO ACESSIBLE RESTROOM WILL MEET ICC/ANSI A117.1 SECTION 404.2.2 . 5) TYPICAL USE OF NEW JERSEY REHABILITATION CODE IS FOR RENNOVATION OF AN EXISTING OCCUPANCY WITHOUT CHANGE OF USE. PLEASE PROVIDE PREVIOUS CofO SHOWING A-2 OCCUPANCY OR OTHER WAY TO JUSTIFY SINGLE UNISEX. CURRENT CODE REQUIRES 2 RESTROOMS IF OCC LOAD IS MORE THAN 15. |
| 12/05/2006 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 12/05/2006 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Revise the plumbing drawings to include the changes shown on the 8-1/2"x 11" sheets. 2. The minimum font size is 1/8", all upper case. 3. Provide upper terminal clean outs for the lavatory and the hand sink. Reference Section 707.4, UPC 2003. 4. The provided water calculations indicate that the minimum water service pipe should be 1", not 3/4" as shown on sheet P-1. Coordinate the water pipe sizes shown on sheets P-1 and the riser diagrams on sheet P-2. All connected demands should be included in the water calculations. |
| 12/05/2006 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
| 12/12/2006 | GBONILL1 | FIRE | REVIEW | Needs Review | |
| 12/12/2006 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 12/12/2006 | GBONILL1 | WWM | REVIEW | Needs Review | |
| 12/12/2006 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review |