Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T06CM06034
Parcel: 116300240

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T06CM06034
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/14/2007 ANDREW CONNOR NPPO REVIEW Denied 1. Each lot within Wildcat Pass requires a separate overlay review and approval for ERZ, HDZ, NPPO, and WASH.

2. The grading plan must indicate that disturbance does not encroach into the ERZ or WASH areas. Revise grading plan to clearly identify disturbance limits. ( See Engineering Comments)

3. Verify if this site has a Conservation Easement issued by Starr Pass Residential LLC. Include with re-submittal.

4. The NPPO shall include an inventory and analysis of all plants listed as Federal Endangered Species, all Saguaros, and all Ironwoods designated as Protected Native Plants according to Sec. 3.8.5. Preservation and mitigation requirements for these genus and species shall conform to Sec. 3.8.6.2.


Add the following notes to grading plan (Including heading):

CITY OF TUCSON
DEVELOPMENT STANDARD NO. 9-04.0
HILLSIDE DEVELOPMENT SITE IMPROVEMENT

Add the following notes to site plan (Including heading):

A. Vegetation Retention.

1. Existing trees with four (4) inch or greater trunk diameter and cacti will be preserved in their original locations, except for building sites and access and utilities serving building sites.

2. When retention of the above trees and cacti in their original locations is not possible due to building site location, the trees and cacti will be salvaged and replanted in areas requiring re-vegetation, whenever possible.

B. Re-vegetation. All cut or fill slopes, which are no steeper than three (3:1) and all utility trenches or septic leaching fields which are not located in parking or driveway areas will be re-vegetated in compliance with the following requirements.

1. All plants used in re-vegetation must be the same as the native vegetation on the site or any adjacent site prior to grading or clearing.

2. Re-vegetation will be accomplished with the following minimum requirements for plants.

a. Native trees, a minimum of fifteen (15) gallon size with a minimum trunk diameter of two (2) inches measured at the soil level, or large specimen cactus will be placed at the same vegetation density found on the site prior to any clearing, grubbing, or grading.

b. Seeds for trees, desert shrubs, and grasses will be planted with a density adequate to control erosion and may use one of the following methods of planting or any other method approved by the Zoning Review Section at DSD.

1) Raked into the soil with appropriate mulch materials;
2) Hydro-seeding;
3) Anchored mulches; or
4) Established on jute, rolled straw, or similar material.

C. A temporary watering system must be installed until the re-vegetation materials is established.

D. Fencing shall be required during construction per DS 2-06.8.0 Fig.1 for all undisturbed natural desert areas of Protected Native Plants and for individual Protected Native Plants to be preserved-in-place. The area to be fenced shall be beyond the "drip-line" of the vegetation by one-half (½) the distance of the "drip-line" radius. For Saguaros and cacti, the area to be fenced shall be equal to the distance of one-half (½) the height of the plant per DS 2-15.6.0

E. NPPO pre permit inspection is required prior to grading inspection can be scheduled by calling IVR system and entering inspection code 09015 or calling Landscape Field Representative directly @ 791-5550 EXT 1140
03/01/2007 ELIZABETH EBERBACH ENGINEERING REVIEW Approved DATE: March 1, 2007
TO: Troy Williams
SUBJECT: 3265 W Big Dipper Dr Site Review Resubmittal
REVIEWER: Elizabeth Eberbach
ACTIVITY NUMBERS: T06CM06034, T06BU02776

Summary: Engineering Division has reviewed the revised site plan at the counter and recommends approval.

GRADING PERMIT CONDITIONS:
The following 2 conditions apply to the Grading Permit:
1) There shall be no encroachment outside of the grading limits and there shall be no encroachment into the Tucson Code Chapter 29 Article VIII Watercourse Amenities, Safety and Habitat Ordinance (WASH) restricted areas. Disturbance outside of the grading limits may result in a Stop Work Order, citation, and/or re-review of the project including SAC review and mitigation.
2) Temporary erosion control devices shall be placed as needed at downstream side of grading limits.

I can be reached at 791-5550, ext.2204 if you have questions.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services Department
03/07/2007 LINHART PETERSEN POERS ASSOC. 2ND PARTY REVIEW REVIEW Approved
03/11/2007 DAVID RIVERA ZONING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
03/20/2007 FSANCHE1 OUT TO CUSTOMER Approved
03/20/2007 SUE REEVES REJECT SHELF Completed