Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T06CM06008
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/03/2007 | GERRY KOZIOL | WWM | REVIEW | Approved | |
12/04/2006 | DAVE MANN | FIRE | REVIEW | Approved | |
12/04/2006 | SUE REEVES | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
12/20/2006 | ROBERT SHERRY | WATER | REVIEW | Approved | |
12/20/2006 | WILLDAN | ADA | REVIEW | Denied | see 2nd party comments |
12/20/2006 | WILDAN | 2ND PARTY REVIEW | REVIEW | Denied | December 19, 2006 City of Tucson Development Services 201 N. Stone Avenue Tucson, AZ 85701 RE: POLICE DEPARTMENT ADA MODIFICATIONS – 1ST REVIEW CITY OF TUCSON LOG NO. T06CM06008 WILLDAN PROJECT NO. 13881-6088 The initial review for the above project has been completed. This letter contains comments which need to be addressed by written responses to each which indicate any actions taken. In order to facilitate a shorter second review, all corrections and revisions must be made on the original plans and two complete new sets of prints, along with one complete redlined set, must be returned to our office. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets, and that all changes have been highlighted with appropriate revision numbers, revision dates, and “cloud bubbles.” Pen or pencil corrections on final prints are not acceptable. This project has been reviewed for conformance with the 2003 IRC, 1997 UAC, 2003 IMC, 2003 IECC, 2002 NEC codes with local modifications, and the 2003 UPC with State of Arizona Amendments. Any revisions to this plan will require an additional review and approval by Willdan. Should you have questions regarding the comments herein, please contact your plans examiner Chris Kiel. Occupancy Occup. Load Construction Area S.F. Sprinklered Alarms N/A N/A N/A N/A N/A N/A GENERAL COMMENTS: Please provide additional dimensions in order to verify compliance with the applicable sections of ANSI 117.1-2003, ADAAG, and 2003 IBC per section 106.1.1 of the 2003 IBC (i.e. hallway dimensions, dimensions inside and outside of the water closet compartments, maneuvering clearances for fixtures and doors, etc.). In addition, please indicate if the existing doors have automatic door openers if they do not provide the required maneuvering clearances. ARCHITECTURAL COMMENTS: Sheet A0.0 Please revise the plumbing code in the summary of government regulations to specify the 2003 UPC as adopted by the City of Tucson. Sheet A0.2 Please provide addition information regarding the lavatories and drinking fountains in order to verify compliance with sections 602 and 606 of ANSI 117.1-2003. Sheet A0.6 Please revise the bench back support to denote compliance with section 901 of ANSI 117.1-2003 (i.e. 2” maximum to a point 18” minimum above the seat surface). Sheet A3.1 Please provide verification that the removal of one of the urinals in the men’s room doesn’t reduce the number below the required minimums per table 2902.1 of the 2003 IBC. Please revise the layout of the women’s accessible water closet compartment to meet the requirements of section 404.2.3 of ANSI 117.1-2003 for the door and section 604 for the water closet compartment. Sheets A3.1 and A4.1 Please provide additional information regarding the control switches for the motorized doors in order to verify compliance with section 404.3.5 of ANSI 117.1-2003. In addition, please provide dimensions at the door and adjacent spaces in order to verify compliance with section 404 of ANSI 117.1-2003. Please provide additional information regarding the maneuvering clearances on the pull side of the doors to the men’s room accessible water closets in order to verify compliance with section 404.2.3 of ANSI 117.1-2003. Please provide verification that the drinking fountains do not exceed the horizontal projection requirements (4” max) of sections 307 of ANSI 117.1-2003 and 1003.3.3 of the 2003 IBC. Sheet A4.1 Please provide the minimum maneuvering clearances for the woman’s accessible water closet door on the pull side per section 404.2.3 of ANSI 117.1-2003. STRUCTURAL COMMENTS: Reviewed and accepted. PLUMBING COMMENTS: Reviewed and accepted. MECHANICAL COMMENTS: Reviewed and accepted. ELECTRICAL COMMENTS: Reviewed and accepted. ACCESSIBILITY COMMENTS: Please refer to the General and Architectural Comments for issues concerning accessibility. Sincerely, WILLDAN Martin Haeberle, C.B.O. Building Official |
12/21/2006 | DAVID RIVERA | ZONING | REVIEW | Denied | Denied until site coments have been addresed. |
12/29/2006 | JASON GREEN | ENGINEERING | REVIEW | Passed |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
01/12/2007 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
01/12/2007 | SUE REEVES | REJECT SHELF | Completed |