Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T06CM05961
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/27/2006 | DAVE MANN | FIRE | REVIEW | Approved | |
| 11/30/2006 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: All Star Auto Exchange T06CM05961 Site Plan (1st Review) TRANSMITTAL DATE: November 30, 2006 COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. This site plan was reviewed for full code compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) due to the 80% lot expansion. 2. It appears that this project is comprised of four (4) different parcels. Prior to approval of the site plan the parcels will need to be combined. Provide a Pima County Tax Parcel Combo and a recorded covenant regarding development and use of real property. Remove the interior lot line from the site plan. 3. Irvington Road is a Major Street and Route (MS&R) with a future right-of-way of one-hundred-twenty (120) feet. This project has not been designed to meet the future right-of-way, therefore either revise the plan to meet the future right-of-way or provide a future site plan indicating how the project will comply with LUC requirements when the MS&R can no longer be used as part of the site. Along with the site plan a recorded Major Streets and Routes Covenant is required, see attached. 4. D.S. 2-02.2.1.A.4 Provide a location map which meets the minimum requirements of D.S. 2-05.2.1.D, show the subject property approximately centered in the one (1) square mile area, identify conditions within the square mile area, such as City of Tucson city limits boundary. 5. D.S. 2-02.2.1.A.7 Provide the required zoning setbacks for the existing building on the site plan. The required setback for Irvington Road, 13th Avenue and 15th Avenue is twenty-one (21) feet or the height of the building, which ever is greatest, measured from the back of existing/future curb. The setback to the north property line is one & one-half the height of the building wall. This north setback is required for both the existing building and the existing storage shed. 6. D.S. 2-02.A.2.1.8 Provide a fully dimensioned layout of the off-street vehicle parking. Provide typical parking space details for both handicapped and standard spaces. This includes the existing parking area, dimension the existing PAALs and parking. Additional comments may be forth coming. 7. D.S. 2-02.A.2.1.8 Dimension the backup spur located on the west end of the existing building. D.S. 3-05.2.2.D 8. D.S. 2-02.A.2.1.9 & D.S. 2-09.0 Provide off-street bicycle parking; including materials for lighting, paving, and security; fully dimensioned layout; location; specific type of rack and the number of bicycles it supports; and the location and type of directional signage if required. The Class 2 bicycle parking must be located with in 50' or the main entrance, D.S. 2-09.4.1, and meet the requirements of D.S. 2-09.0 Supplement 09. 9. D.S. 2-02.A.2.1.10 The Sight Visibility Triangles (SVTs) shown at the PAALs along 13th & 15th appear to be incorrect, See engineering comments. Provide the future SVTs on the plan, see comment 3. 10. D.S. 2-02.A.2.1.11 Provide a dimensions on the existing entrance PAALs. 11. D.S. 2-02.2.1.A.12 Provide dimensions for the width of all existing sidewalks and pedestrian ways. 12. D.S. 2-02.2.1.A.12 & D.S. 2-08.3.1 A pedestrian circulation path/accessible route is required to connect all public access areas of the development to the pedestrian circulation paths located in any adjacent streets. The existing pedestrian circulation path shown from the existing building to the sidewalk along Irvington Road does not appear to meet the requirements for an accessible route, clarify. The existing pedestrian circulation shown along the north property line east of the building does not appear to meet the requirements for an accessible route, clarify. There is not a pedestrian circulation path/accessible route shown from the existing building to 15th Avenue, provide one. 13. D.S. 2-02.2.1.A.12 Stripe the handicapped access aisle. 14. D.S. 2-02.2.1.A.12 Detectable warnings (truncated domes) will be required at all curb access ramps. ICC/ANSI A117.1-2003 Sec. 406.13 15. D.S. 2-02.2.1.A.12 Indicate how the bicycle parking spaces will be accessed, see D.S. 2-09.0 for requirements 16. D.S. 2-02.2.1.A.13 If applicable provide the location, type, size and height of existing and proposed freestanding signage and billboards. 17. D.S. 2-02.2.1.A.19 The existing right-of-way for Irvington Road appears to be incorrect. See engineering comments. Future right-of-way is required to be shown on the plan, see comment 3. 18. D.S. 2-02.2.1.A.25 If applicable provide existing and proposed freestanding lighting layout and type. Provide a detail; list the height of pole and type of lighting. 19. D.S. 2-02.2.1.A.21 Provide dimension from street monument lines to existing and future curbs, see comment 3. 20. D.S. 2-02.2.1.A.25 Provide proposed lighting layout for the proposed additional display area along will type and detail. 21. D.S. 2-02.2.1.A.28 The existing zoning shown on the east side of 13th Avenue to the north is in correct. The zoning in that area is "P", directly to the east of this project is "C2". 22. D.S. 2-02.2.2.4 The bicycle parking calculation is incorrect. Based LUC Sec 3.3.3.5 the minimum number of bicycle parking spaces required is 2. Zone acknowledges that per LUC Sec 3.3.7.8A that Class 2 may be substituted for Class 1 when less then 50 vehicle parking spaces are provided. 23. D.S. 2-02.2.2.5 Provide the number of loading zones required and provided. 24. D.S. 2-02.2.2.5 Provide a calculation for the lot expansion. 25. Ensure that all changes to the site plan are reflected on the landscape & grading plan. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 791-5608 ext. 1180. C:\planning\site\t06cm05961.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents |
| 12/06/2006 | STEVE SHIELDS | ZONING HC SITE | REVIEW | Denied | See Zoning Comments |
| 12/06/2006 | SSHIELD1 | ADA | REVIEW | Passed | |
| 12/11/2006 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1. A street landscape border, per Sec. 3.7.2.4 of the LUC, is a landscape area with a minimum width of ten (10) feet, running the full length of the street property line(s) bounding the site except for points of ingress-egress. On streets designated as Major Streets and Routes (MS&R), the street landscape border is measured from the MS&R right-of-way line as determined by LUC 2.8.3.4. Verify ROW measurements along Irvington Rd. Landscape borders along 13th Ave. are less than 10' revise plan as necessary. 2. An approved site plan is required indicating how the project will comply with LUC requirements when the MS&R right-of-way can no longer be used as part of the site. Such plan is to be an exhibit to an executed covenant for recordation stating the responsibility of the property owner, successor, or assignee as to the removal of improvements and compliance with the LUC at no cost to the City. 3. Street landscape borders shall be located entirely on site, except that, if approved by the City Engineer or designee. Up to five (5) feet of the required ten (10) foot width be placed within the adjacent right-of-way area or within the Major Streets and Routes (MS&R) right-of-way area on MS&R streets. 4. Fifty (50) percent or more of the street landscape border area must have shrubs and vegetative ground cover per LUC 3.7.2.4. Verify vegetative coverage along Irvington Rd. 5. Include inside dimensions of strip planters and areas for required trees within vehicle use area on the landscape plan. A minimum of 4' in width must be provided for each canopy tree. The measurement is always within the planter area and does not include any material which defines the outer edge of the unpaved area per DS 2-06.3.3.C. 6. The site plan and landscape plan must show identical site layout to avoid conflict between the two plans. Include any changes or information to the site plan on the landscape plan as well. 7. Include location of all screening elements on the landscape plan indicated on site plan. A 5' wall to screen vehicle use and display areas from residential zoned properties must be provided per LUC Table 3.7.2-I. 8. Add note to landscape plan: ALL LANDSCAPE AREAS SHALL BE DEPRESSED A MAXIMUM OF 6' TO ACCOMODATE WATER HARVESTING. 9. Additional comments may apply. |
| 12/11/2006 | ANDREW CONNOR | NPPO | REVIEW | Approved | Exception. |
| 12/29/2006 | JASON GREEN | ENGINEERING | REVIEW | Denied | DATE: December 29, 2006 SUBJECT: 702 W Irvington Road- Engineering Review of Site Plan and Grading Plan TO: MPE LOCATION: T14S R13E Sec35, Ward 1 REVIEWERS: Jason Green, CFM ACTIVITY: T06CM05961 (Site Plan) and T06BU02734 (Grading Plan) SUMMARY: Engineering Division of Development Services Department has received and reviewed the site plan, grading plan, and Drainage Report (prepared by DCC) for the above referenced property. Engineering Division does not recommend approval of the site plan or grading plan at this time. The following items need to be addressed: SITE PLAN COMMENTS: The site plan has been reviewed for full code compliance with the City of Tucson Development Standards and Land Use Code due to lot expansion. This includes existing and proposed improvements. 1) DS Sec.2-02.2.1.A.2: Revise the Township, Range and Section portion of the location plan to read T14S, R13E Sec 35. 2) DS Sec.2-02.2.1.A.4: Revise the project location map on Sheet C1.1 to identify conditions within the square mile shown, such as section corners, watercourses and subdivisions adjacent to the site. Reference recorded subdivision plats by book and page numbers. 3) DS Sec.2-02.2.1.A.5: Provide recordation information showing that all lots have been combined. Lot combination is required prior to site plan approval. 4) DS Sec.2-02.2.1.A.8: Provide a fully dimensioned offsite street-parking layout. Provide dimensions for PAALs and parking spaces. Existing parking must be shown and dimensioned to verify compliance with Development Standards 3-05.0. 5) DS Sec.2-02.2.1.A.8: Provide a dimensioned back-up spur at the end of the row of parking located on the west side of the building with a minimum of 3 feet in depth, 3-foot radii, and a wheel barrier to prevent encroachment onto any unsurfaced area. Label all dimensions for proposed back-up spurs. 6) DS Sec.2-02.2.1.A.10: Provide the existing and future sight visibility triangles for all intersections of the PAALs at Irvington Road. Refer to DS Sec.3-01.5.1 for sight visibility requirements and dimensions. 7) DS Sec.2-02.2.1.A.10: Revise the SVT triangle at the intersection of 15th Avenue and Irvington Road. Near side dimension for a local street intersecting an Arterial Street is 340-feet. Provide both existing and future SVT. 8) DS Sec.2-02.2.1.A.11: Verify and label the 18-feet radii and concrete curbs per City of Tucson Transportation Access Management Guidelines (TAMG), Section 5.5 at the driveway entrances located on 15th Avenue. Refer to DS Sec.3-01.3.2.C for street development standards. For use of standard driveway aprons approval from City of Tucson Traffic Engineering is required, contact Jose Ortiz, P.E. at 791-4259 for further information. 9) DS Sec.2-02.2.1.A.11: Provide the dimensions for all access points located along Irvington Road. Verify minimum dimensions for all access points are labeled and shown. Refer to Tucson Code, Chapter 25, and Section 25-39 for driveway and curb cut requirements. 10) DS Sec.2-02.2.1.A.12: Revise the site plan to show that all transitions from pedestrian circulation to vehicular use area have truncated domes per ANSI Standards A117.1-2003 Section 406.13. Provide the dimensions on the details with the minimum requirements. 11) DS Sec.2-02.2.1.A.12: Revise the site plan and Keynote 32 to label the required 5-foot wide sidewalk along 15th Avenue. Label all proposed pedestrian circulation paths around the buildings as 4-feet or 5-feet where adjacent to a PAAL or parking stalls. 12) DS Sec.2-02.2.1.A.12: Revise the site plan to show the required pedestrian circulation path from the existing building to the pedestrian circulation path proposed along the frontage of 15th Avenue. Pedestrian circulation must be 5-feet in width were adjacent to a PAAL and a structure. Refer to DS Sec 2-08 and 3-01 for further details. 13) DS Sec.2-02.2.1.A.12: Provide verification on the site plan that there is an unobstructed 4-foot wide pedestrian access around the existing refuse collection containers and around the entire existing building. Verify that the pedestrian circulation paths from Irvington Road and 13th Avenue access points have the required 4-feet width or 5-feet where adjacent to a PAAL. 14) DS Sec.2-01.2.1.A.19: Revise the site plan to label the recordation information for 13th and 15th Avenue and Irvington Road. 15) DS Sec.2-02.2.1.A.19: Revise the site plan to show and label the MS&R future right-of-way width for Irvington Road. No improvements are allowed to be constructed within the future right-of-way. 16) DS Sec.2-01.2.1.A.20: Provide the Book and Page for the utilities that are within the alleyway and shown on the site plan. If the Utilities are under one record a General Note can be used to provide the recordation information. 17) DS Sec.2-01.2.1.A.21: Provide dimensions from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines. GRADING PLAN: 18) DS Sec.11-01.2.1: The grading plan can not be approved prior to site plan approval. All comments associated with the site plan must be corrected and the site plan must be approved prior to grading plan approval. Ensure that the grading plan reflects the corrected and final site plan. 19) Please ensure that any future grading plan will be consistent with the site plan and drainage report. Grading standards may be accessed at: http://www.ci.tucson.az.us/dsd/DevStandsTOC.pdf GENERAL COMMENTS: Please provide a revised site plan and grading plan that address the comments provided above. Include a comprehensive response letter addressing in detail responses to all of the above comments. Further comments may be generated upon resubmittal of the site plan and grading plan. Please enclose "redlines" with the resubmittal package for reference. If you have any questions, or to schedule an appointment, I can be reached at 791-5550, extension 1189. Jason Green, CFM Senior Engineer Associate Engineering Division Development Services |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/03/2007 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 01/03/2007 | SUE REEVES | REJECT SHELF | Completed |