Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T06CM05909
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/15/2006 | TERRY STEVENS | ZONING | REVIEW | Approved | |
| 11/15/2006 | PATRICIA GILBERT | ENGINEERING | REVIEW | Approved | |
| 11/24/2006 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Correct the arithmetic for the water fixture units. Reevaluate the required size of the water service pipe. 2. Clarify the drainage for the foot spas. Gravity drains shall be directly wasted. 3. Justify the flat vent for the new water closet. |
| 11/24/2006 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
| 11/24/2006 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 11/24/2006 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 11/27/2006 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Denied | T06CM05909 11/27/06 1. Recirculation pump is cord connected. Reference Sheet P4. 2. Provide mounting height, luminaire cut sheets, and any other information necessary to determine compliance with NEC 680.43 (B). 3. Plans Examiner got 13810 VA on Phase A, not 11495. 4. Total current for Panel A exceeds its 100A capacity. 5. Panel schedule calls for 100A panel. One Line Diagram calls for 200A panel. Please clarify. |
| 11/27/2006 | CHRISTY FOREMAN | BUILDING-COMMERCIAL | REVIEW | Denied | 1) Provide water fountain HIGH AND LOW PER PER 602.4 2) Provide exit accessibility for door of north restroom. |
| 12/22/2006 | CAGUILA1 | WWM | REVIEW | Needs Review | |
| 12/22/2006 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/22/2006 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |