Permit Review Detail
Review Status: Completed
Review Details: OTHER
Permit Number - T06CM05809
Review Name: OTHER
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/16/2006 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Approved | PLAN CHECK COMMENTS - PROJECT #T06CM05809 11/16/06 5202 E. 25th STREET PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2003 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. FOUNDATION PLANS: 1. THE USE OF EPOXY FOR THE INSTALLATION OF THE SLAB / SLAB DOWELS REQUIRES A SPECIAL INSPECTION. THE FORMS ARE AVAILABLE AT THE PERMIT COUNTER. FLOOR PLANS: 1. PLEASE DIMENSION THE SOUTH SIDE OF THE CARPORT. (BEAM SPANS) STRUCTURAL PLANS: 1. PLEASE SPECIFY THE SOUTH PORCH RAFTERS. 2. PLEASE SPECIFY THE COMBINATION SYMBOL FOR THE GLUE LAM. 24F-V4 ? 3. PLEASE EXPLAIN YOUR DETAIL NUMBERING SYSTEM. DOES THE TOP INDICATE THE DETAIL NUMBER AND THE BOTTOM INDICATE THE PAGE? "R"? SECTIONS - DETAILS - MISC. NOTES: 1. C / 4 ; PLEASE SPECIFY THE R-VALUES OF THE INSULATION FOR THE 2X6 WALLS AND THE U-VALUE FOR THE WINDOWS. 2. PLEASE PROVIDE THE SPACING OF THE LTP5s , LTP4s AND THE HDQ8s AS NOTED ON THE FOUNDATION PLAN. CLARIFY "LTP5 to LTP4". MECHANICAL PLANS: 1. UNLESS THE AREA OF THE WALL COMMON TO THE NEW DEN AND THE EXISTING KITCHEN/DINING AREA IS 50% OPEN , A SOURCE OF HEAT IS REQUIRED IN THE NEW DEN. ELECTRICAL PLANS: 1. IN THE NEW DEN, PLEASE PROVIDE A RECEPTACLE WITHIN 6 FEET OF THE LAUNDRY DOOR AND WITHIN 6 FEET OF THE OPENING TO THE KITCHEN/DINING AREA OPENING. 2. T.E.P. REQUIRES A 2 ½" RISER TO THE METER SECTION OF THE ELECTRIC PANEL. 3. GENERAL NOTES AND CONDITIONS, NOTE 1 ; PLEASE CHANGE THE 1994 UPC TO THE 2003 UPC. 4. A RECEPTACLE IS REQUIRED AT EACH KITCHEN COUNTER TOP 12" WIDE AND WIDER. (ie TO THE RIGHT OF THE KITCHEN SINK). THE KITCHEN TOPS ARE REQUIRED TO BE SERVED BY NOT LESS THAN 2 15AMP 5. THE RECEPTACLES AT THE KITCHEN COUNTER TOPS ARE REQUIRED TO BE SPACED SO THAT NO WALL BEHIND THE TOP IS OVER 4 FEET FROM A RECEPTACLE. 6. BED ROOMS ; PLEASE PROVIDE A RECEPTACLE WITHIN 6 FEET OF THE DOORS. 7. M / BR ; PLEASE PROVIDE A RECEPTACLE ON THE PIECE OF WALL OVER 2 FEET WIDE BETWEEN THE DOOR TO THE BEDROOM AND THE CLOSET DOOR. 8. PLEASE PROVIDE ARC FAULT PROTECTION FOR THE BEDROOM OUTLETS. 9. PROVIDE SMOKE DETECTORS FOR THE BED ROOMS AND IN THE AREA IMMEDIATELY OUTSIDE THE BED ROOMS. 10. IS THE HOUSE BEING RE-WIRED OR JUST THE ADDITION? REMOVE THAT WHICH DOESN'T APPLY. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 791-5550 EXT. 1110 |