Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T06CM05803
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/09/2006 | DAVE MANN | FIRE | REVIEW | Approved | |
| 11/09/2006 | BETSY COTTLE | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 11/20/2006 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Revise the font size used on the drawings to a minimum of 1/8-inch (all upper case). Reference Section 302.3, Uniform Administrative Code, 1997. 2. Clarify the nature of an "open site drain" as noted in the plumbing fixture schedule. Reference Section 103.2.3, UPC 2003. 3. Provide a floor drain in the kitchen. Reference Section 412.2, UPC 2003. 4. Include backflow prevention devices to be used with specific kitchen equipment (e.g. espresso, chemical dispenser) in the plumbing fixture schedule. Appliances to be directly connected to the water supply system that do not have listed, integral backflow preventers or integral air gaps require backflow protection. Reference Section 603.0, Table 6-2, and Table 6-3, UPC 2003 5. Provide upper terminal cleanouts on horizontal drainage pipes exceeding 5 feet in length (horizontal drain lines serving sinks require cleanouts regardless of length). Reference Section 707.4, UPC 2003. 6. Provide a direct waste connection for the wash and rinse sections of the 3-compartment sink, with an indirect connection for the sanitizing compartment only. Reference Sections 304.0 and 801.2, UPC 2003 7. Provide a direct waste connection for the pre-rinse sink. Reference Sections 304.0 and 801.2, UPC 2003 8. Modify trap arm lengths to conform to Table 10-1, UPC 2003. Reference Section 1002.2, UPC 2003. 9. Provide justification for connecting the dishwasher the pre-rinse sink waste lines to the sanitary waste instead of the kitchen waste. Reference Section 1014.1, UPC 2003. |
| 11/20/2006 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 11/20/2006 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Revise the font size used on the drawings to a minimum of 1/8-inch (all upper case). Reference Section 302.3, Uniform Administrative Code, 1997. 2. Provide the installed weight of the fan coils (FC-1 and FC-2). Provide structural calculations and details to show how the fan coils are attached to the building structure. Reference Sections 106.3.1 and 302.1, IMC 2003. 3. Provide calculations showing that adequate outside air is being provided to the rooms in the project area. Reference Section 403.3 IMC 2003. 4. Provide the installed weight of the Type II exhaust hoods. Provide structural calculations and details to show how the hoods are attached to the building structure. Reference Sections 106.3.1, 302.1, and 507.6, IMC 2003. 5. Provide exhaust volumes for the kitchen hood per Section 507.13.4, IMC 2003. 6. Clarify how the scheduled amount of makeup air for the dishwasher complies with the volume requirements of Section 508.1, IMC 2003. |
| 11/24/2006 | SREEVES1 | WWM | REVIEW | Denied | needs 8th floor credit evaluation |
| 12/01/2006 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Denied | TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL. PLEASE CALL AT 791-5550 X1106 OR EMAIL AT Linda.Buczynski@tucsonaz.gov IF YOU CARE TO DISCUSS. THIS IS AN INCOMPLETE REVIEW. SEE COMMENTS #1 AND #2 BELOW. 1. Revise the font size used on the drawings to a minimum of 1/8-inch (all upper case). Reference Section 302.3, Uniform Administrative Code, 1997. 2. Panel schedules and lighting schedule font size too small for complete review. Will review branch circuits, feeders and other electrical loads after Comment #1 above is resolved. 3. Protect Panel K1 according to the requirements of NEC 408.16 (A). 4. Protect Panel K2 according to the requirements of NEC 408.16 (A). 5. Provide the size of the bond on the secondary of the 150 KVA X'FMR. Reference NEC Table 250.66. 6. Provide manufacturer certification that listing of 1600A distribution board will not be violated with the tap proposed in Alternate #1. 7. Specify line side and load side ratings of any and all series-rated combinations. Provide fault calculations sufficient to demonstrate that higher rating is adequate. The MCB on Panel LP1 implies a 3-tiered rating, not necessarily available in the industry: provide manufacturer cut sheets and verification. Please note that in the case that Alternate #2 is employed, the magnitude of fault currents on the secondary side of the transformer may be such that such ratings are not necessary. |
| 12/07/2006 | CHRISTY FOREMAN | BUILDING-COMMERCIAL | REVIEW | Denied | 1) PLEASE CLARIFY (DETAIL) HOW NEW STEEL (W8 COLUMNS AND W10 BEAMS WILL MEET 2 HR FIRE RESISTIVE CONSTRUCTION FOR TYPE II-FR BUILDING. 2) CLARIFY FIELD WELDING ON PLANS. 3) DETAIL 2/A2 AND 7/A2.1...FIRE RETARDANT PLYWOOD REQUIRED FOR NON COMBUSTIBLE FRAMING. 4) PROVIDE DETAILS FOR STRUCTURAL SUPPORT OF SUSPENDED ACCOUSTICAL CIELINGS, GYPSUM BOARD CIELINGS AND GYPSUM SOFFITS. 5) PROVIDE WEIGHT OF SUSPENDED PANELS WITH # AND LOCATIONS OF HANGER RODS PER DETAIL 5/A2.1. 6) VERIFY MINIMUM PLUMBING FACILITIES HAVE BEEN MET FOR INCREASED OCCUPANT LOAD OF ASSEMBLY AREA. 7) ACCESSIBILITY NOTES PP C1 SHOULD INDICATE DOORS HAVE A -MAXIMUM- OPENING FORCE OF 5 LBF. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/04/2007 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 01/04/2007 | SUE REEVES | REJECT SHELF | Completed |