Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T06CM05801
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/13/2006 | CHRISTY FOREMAN | BUILDING-COMMERCIAL | REVIEW | Denied | CITY OF TUCSON DEVELOPMENT SERVICES STRUCTURAL REVIEW COMMENTS DATE: 5/19/06 ACTIVITY NUMBER: T06CM02118 PROJECT NAME: T.I. Inspectors office space Development Services PROJECT ADDRESS: 406 N. Church ARCHITECT / ENGINEER: Lizard Rock Designs PROJECT REVIEWER: Christy Foreman 1) PROVIDE CLEAR TURNING RADIUS AT BACK DOOR PER ANSI A117.1 2003 SECTION 405.7.5. 2) PROVIDE CLARIFICATION THAT THE BREAKROOM COUNTER IS PER ANSI A117.1 2003 PER SECTION 1003.12.4.2 3) CLARIFY DEPTH OF FOOTING BELOW GRADE FOR NE COLUMNS. 4) CLARIFY ON DETAIL 2/S1.0 LOCATION OF BASE OF WALL REINFORCEMENT PER STRUCTURAL CALCULATIONS. sPACING 16" O.C. 5) CLARIFY ON DRAWINGS DIMENSIONS BETWEEN COLUMNS / BEAM SPAN TO JUSTIFY STRUCTURAL CALCULATIONS. SHT. A1.0 DOES NOT SHOW INFORMATION AND SHT. S2.0 DOES NOT SPECIFY. NEED TO CLARIFY SPAN AND OVERHANG PER STRUCTURAL CALCULATIONS. 6) CLARIFY IF THERE IS A CONNECTION FOR OVERHANG OF NEW STEEEL BEAM TO EXISTING STEEL BEAM. |
| 11/14/2006 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
| 11/14/2006 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Denied | TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL. PLEASE CALL AT 791-5550 X1106 OR EMAIL AT Linda.Buczynski@tucsonaz.gov IF YOU CARE TO DISCUSS. 1. Provide a disconnecting means for the Power Door Opener. 2. Allowed lumens according to the Tucson Lighting Code appears to be 57,000, not 5,700. |
| 11/14/2006 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 11/14/2006 | HEATHER THRALL | ZONING | REVIEW | Approved | |
| 11/14/2006 | DAVE MANN | FIRE | REVIEW | Denied | Provide documentation that doors are 1-hour rated (with closers) to comply with the exceptions to travel distances according to IBC 2003, Section 1014.2.1. Otherwise, building must be sprinklered. |
| 11/14/2006 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1.Provide an accessible drinking fountain. Reference Chapter 2900, IBC 2003. 2. Water heaters without integral heat traps shall have the first 8' of piping insulated per Section 804.5, IECC 2003. Clarify if the pipe insulation specification on sheet MP1 applies to this activity. |
| 11/17/2006 | SREEVES1 | WWM | REVIEW | Needs Review | |
| 11/17/2006 | SREEVES1 | ADA | REVIEW | Needs Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/17/2006 | SUE REEVES | OUT TO CUSTOMER | Completed |