Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T06CM05798
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/25/2007 | LINHART PETERSEN POERS ASSOC. | 2ND PARTY REVIEW | REVIEW | Denied | February 23, 2007 CITY OF TUCSON-SECOND CHECK Tucson Appl. No. T06CM05798 Bureau Veritas Project No. 01006-161098 LVH Construction Inc. 1705 N. Country Club Road Tucson, Arizona 85716 Re: Plan Review: LVH Construction-Addition Address: 4029 E. Paseo Grande Dear LVH Construction Inc. Bureau Veritas North America has completed a second review of the following documents on behalf of the City of Tucson: Plans: Two (2) Copies of plans (8 sheets, 1-8) no dates or stamps. Structural Calculations: None submitted with this review. These documents were reviewed only for their conformance to the provisions of the 2003 International Building Codes (i.e. State of Arizona and Tucson amended 2003 IRC, 2003 IMC, 2002 NEC and 2003 IPC). Please submit an itemized response letter and required number of complete and revised documents with all revisions clouded. Sincerely, Bureau Veritas North America Randy McCoy ICC Plans Examiner RMC: sk Enclosures LVH Construction Inc-Addition 4029 E. Paseo Grande City of Tucson- Second Check Bureau Veritas Job No. 01006-161098 Page 2 Re: Stories: One Fire Sprinklers: No Building Area: 720 S.F. (Livable) 240 S.F. (Porch) 550 S.F. (Garage) 1510 (Total S.F.) Floor Plan Comments: An attic access opening shall be provided to attic areas that exceed 30 square feet and have vertical height of 30 inches or greater. The rough-framed opening shall not be less than 22 inches by 30 inches and shall be located in a hallway or other readily accessible location. A 30 inch minimum unobstructed headroom in the attic spaces shall be provided at some point above access opening. IRC Section R807.1 (at garage) Building Cross Section: Section A-A does not correspond with plan on page 5A. Please provide dimensions or otherwise indicate height to top plate IRC Section R106 Roof Plan Comments: Please provide attic ventilation calculations for all concealed attic spaces; include required and provide net free ventilation area. Also indicate the type and location of attic ventilation. IRC Section R806. Framing Plan Comments: 1. Indicate the size and span of headers and lintels in all bearing and non-bearing walls on plan. I Page 3 Plumbing Plan: 1. Provide a gas isometric with length of line (horizontal and vertical) to each appliance, BTU demand of each appliance, size of each branch, total demand and size of meter. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/16/2007 | FSANCHE1 | OUT TO CUSTOMER | Completed |
| 03/16/2007 | SUE REEVES | REJECT SHELF | Completed |