| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/12/2007 | JOE LINVILLE | NPPO | REVIEW | Denied | Submit Application for Exception; include acceptable documentation, which clearly indicates that the project will not impact Protected Native Plants. |
| 01/22/2007 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1. Applications within the Scenic Corridor Zone (SCZ) shall be reviewed in accordance with the DSD Full Notice Procedure, Sec. 23A-50 and 23A-51. Contact Patricia Gehlen for additional information. Indicate on the plans the 400' overlay boundary. 2. Landscape section cannot approve the site plan until the Special Exception has been approved and all zoning comments and concerns have been addressed. 3. Submit Application for Exception; include acceptable documentation, which clearly indicates that the project will not impact Protected Native Plants. 4. Additional comments may apply |
| 01/30/2007 | TERRY STEVENS | ZONING | REVIEW | Approved | |
| 02/27/2007 | ANY | ENGINEERING | REVIEW | Denied | To: Declan Murphy DATE: February 27, 2007 Architect 2612 W. Broadway Blvd. Tucson, Arizona 85782 SUBJECT: T-mobile, 4110 S. Houghton Road Site plan T06CM05796 (Second Review) T14S, R15E, Section 35 RESUBMITTAL REQUIRED: Site Plan and Drainage Statement. The Site Plan (SP) and Drainage Statement (DS) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Site Plan: 1. Please include a response letter to the comments along with the corrected copies of the SP. 2. All easements of record shall be recorded by docket and page and shown on the plans prior to site plan approval. Drainage Statement: 1. Please include a response letter to the comments along with the corrected copies of the DS. 2. A Drainage Statement is a brief description of drainage conditions applicable for a site which are not affected by 100 year flows of 100 cfs, of more……per S.M.D.D.F.M., chap. II, 2.1.2. The DS must be submitted along with the site plan and accepted with the approval of the grading plan. 3. The content and format of the Drainage Statement should follow S.M.D.D.F.M., chap. II, 2.2. 4. Show the project address or administration address on the cover sheet of the DS If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1193 office (520) 879-8010 fax C:/4110 S. Houghton Rd Site 2 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/02/2007 | FSANCHE1 | OUT TO CUSTOMER | Completed |
| 03/02/2007 | SUE REEVES | REJECT SHELF | Completed |