Permit Number: T06CM05777
Parcel: 130055630

Address:
2343 S MCFEE SV

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T06CM05777
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/21/2007 STANTEC 2ND PARTY REVIEW REVIEW Denied February 20, 2007


To: Steve Long, Acting Building Official
City of Tucson Development Services Department
201 N. Stone Avenue, First Floor
Tucson, Arizona 85701

Re: Lizzaraga Residence - Addition
City of Tucson No. T06CM05777
Stantec Project No. 816-30015-01 (090)




Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back-check time, we request that you please provide revised plans and calculations, clouding any changes, along with a written response to each of the noted items indicating the action taken.

SCOPE OF REVIEW:

The scope of this review covers Architectural, Structural, Plumbing, Mechanical, Model Energy and Electrical codes. All code references are to the 2003 International Residential Code (IRC) except for plumbing, which is to the 2003 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL:

There are no general comments to be addressed.

ARCHITECTURAL:

There are no architectural comments to be addressed.

STRUCTURAL:

The following previously made comment has been partially addressed. Provide manufacturer’s calculations and data for pre-fabricated trusses or provided a note on the plans indicating that the trusses drawing submittal shall be deferred. If you elect to defer this submittal then you must obtain written approval by the building official first before we can approve these plans. A note has been provided on the plans by the applicant as requested, however the applicant has not obtained written approval from the building official to defer this submittal. Submit a letter requesting the deferral of the truss drawings for this project to the building official and obtain his signature. Then give us a copy of the letter with his signature and this issue will be resolved. We have received the truss drawings instead of a letter requesting a deferred submit which is acceptable. Having reviewed the truss drawings and compared them to the framing plans, the two documents do not match. Please coordinate between the truss drawings, the roof framing plans, and the elevations. {The elevations show a centered ridge while the trusses show the ridge significantly offset.}

PLUMBING:

There are no plumbing comments to be addressed.

MECHANICAL:

There are no mechanical comments to be addressed.

ELECTRICAL:

There are no electrical comments to be addressed.

ENERGY:

There are no energy comments to be addressed.

-End of Review-

If you have any questions, please call (520) 750-7474.

Sincerely,
Stantec Consulting Inc.



Joel Svoboda
Associate

JS:js

Attachments: none