Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T06CM05763
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/30/2007 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 04/30/2007 | SREEVES1 | 2ND PARTY REVIEW | REVIEW | Denied | April 25, 2007 CITY OF TUCSON - SECOND CHECK Tucson Appl. No. T06CM05763 Bureau Veritas Job No. 01007-161001.008 Mr. George Jenson 501 E. 1st. St. Tucson, Arizona 85705 Re: Plan Review: Jenson Guest House Address: 501 E 1st St. Dear Mr. Jenson, Bureau Veritas North America has completed a second review of the following documents on behalf of the City of Tucson: Plans: Two (2) sets of building plans (9 sheets, 1 though 9) no dates, no stamps. Structural Calculations: None submitted with this review. Truss Calculations: None submitted with this review. These documents were reviewed only for their conformance to the provisions of the 2003 International Building Codes (i.e., State of Arizona and Tucson amended 2003 IRC, 2003 IMC, 2002 NEC and 2003 IPC). Please submit an itemized response letter and required number of complete and revised documents with all revisions clouded. Sincerely, Bureau Veritas North America Randy McCoy ICC Plans Examiner Re: Stories: One Occupancy: R-3/VB Building Area (sq. ft.): 650 (livable) 109 (porch) 745 (garage) 1504 Total sq. ft. A. The following plan review comments are based on the City of Tucson Building Regulations and referred to the 2003 International Building Code. B. Please respond in writing to each comment by marking the attached comment list or creating a response letter. Indicate which detail, specification, or calculation shows the requested information. Your complete and clear responses will expedite the re-check and hopefully, approval of this project. Thank you for your assistance. C. These plan review comments are based on building code items only. If site-related comments are applicable to this project, they will be generated by others (e.g., County Engineering, Public Works, Health, etc.). ROOF PLAN COMMENTS: Provide attic ventilation calculations for all concealed attic spaces; include required and provided net free ventilation area. Also, indicate the type and location of attic ventilation. Provide the following note, if applicable; “Where eave or cornice vents are installed insulation shall not block the free flow of air. A minimum of 1 inch space shall be provided between the insulation and roof sheathing at the location of the vent” IRC Section R806. !f you have any questions regarding the above comments, please contact Randy McCoy at (520) 820-1980 between 8:00 A.M. to 5:00 P.M., M-F. |
| 05/03/2007 | PATRICIA GILBERT | ENGINEERING | REVIEW | Approved | |
| 05/10/2007 | TERRY STEVENS | ZONING | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/17/2007 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 05/17/2007 | GERARDO BONILLA | REJECT SHELF | Completed |