Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T06CM05763
Parcel: 117020440

Address:
501 E 1ST ST #02

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T06CM05763
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/20/2007 LINHART PETERSEN POERS ASSOC. 2ND PARTY REVIEW REVIEW Denied February 14, 2007 CITY OF TUCSON - FIRST CHECK
Tucson Appl. No. T06CM05763
Bureau Veritas Job No. 01007-161001.008

Mr. George Jenson
501 E 1st St.
Tucson, Arizona 85705


Re: Plan Review: Jenson Guest House
Address: 501 E 1st St


Dear Mr. Jenson,

Bureau Veritas North America has completed a first review of the following documents on behalf of the City of Tucson:

Plans: Two (2) sets of building plans (9 sheets) no dates, no stamps.

Structural Calculations: None submitted with this review.

Truss Calculations: None submitted with this review.


These documents were reviewed only for their conformance to the provisions of the 2003 International Building Codes (i.e., State of Arizona and Tucson amended 2003 IRC, 2003 IMC, 2002 NEC and 2003 IPC).

Please submit an itemized response letter and required number of complete and revised documents with all revisions clouded.


Sincerely,

Bureau Veritas North America



Randy McCoy
ICC Plans Examiner








RM:tm s:/tucson\01007-161001.008pc1
enclosures


Re: Stories: One
Occupancy: R-3/VB
Building Area (sq. ft.): 650 (livable)
109 (porch)
745 (garage)
1504 Total sq. ft.

A. The following plan review comments are based on the City of Tucson Building Regulations and referred to the 2003 International Building Code.

B. Please respond in writing to each comment by marking the attached comment list or creating a response letter. Indicate which detail, specification, or calculation shows the requested information. Your complete and clear responses will expedite the re-check and hopefully, approval of this project. Thank you for your assistance.

C. These plan review comments are based on building code items only. If site-related comments are applicable to this project, they will be generated by others (e.g., County Engineering, Public Works, Health, etc.).



FLOOR PLAN COMMENTS:

Provide a calculation to determine the percentage of glazing of the gross area of the exterior walls. Calculations to verify compliance with the 2000 International Energy Code will be required when the glazing area exceeds 15 percent of the gross area of the exterior walls. IRC Section N1101.2.

Provide the following note: A separate insulation inspection prior to drywall or an insulation certificate will be required at time of final. IRC Section N1101.3.1.

An attic access opening shall be provided to attic areas that exceed 30 square feet and have a vertical height of 30 inches or greater. The rough-framed opening shall not be less than 22 inches by 30 inches and shall be located in a hallway or other readily accessible location. A 30 inch minimum unobstructed headroom in the attic space shall be provided at some point above the access opening. IRC Section R807.1.


ROOF PLAN COMMENTS:

Provide attic ventilation calculations for all concealed attic spaces; include required and provided net free ventilation area. Also, indicate the type and location of attic ventilation. Provide the following note, if applicable: "Where eave or cornice vents are installed insulation shall not block the free flow of air. A minimum of 1 inch space shall be provided between the insulation and roof sheathing at the location of the vent”. IRC Section R806.


FRAMING PLAN COMMENTS:

TRUSS SYSTEMS: Trusses can be submitted as a “Deferred Submittal” for custom homes only. However, they must be submitted and approved prior to their fabrication.

Provide complete truss calculations and truss layout plan. Truss designs submitted must include all types and be designed for the loading conditions, span, slope, and spacing designated on the framing plan.
Truss calculations must be signed, dated and sealed by an Engineer who is registered in the State of Arizona.

The seal on the truss calculations shall be dated within the latest adopted IRC.

All truss calculations shall be cross-referenced to the truss layout or the roof and floor framing plans.

Specify all hangers used to hang trusses from girder trusses, walls, or other locations. IRC Section R802 & ANSI-TPI 1995.


MECHANICAL COMMENTS:

Show condensate line and secondary condensate line. IRC Section M1411.3 and M1411.3.1.


PLUMBING COMMENTS:

Specify if appliances and equipment are gas, electric, or propane. Reference location of appliances and equipment.


ELECTRICAL COMMENTS:

Provide a convenience receptacle outlet for the servicing of appliances (HVAC) within 25 feet of the appliance. IRC Section 3801.


If you have any questions regarding the above comments, please contact Randy McCoy at (520) 820-1980 between 8:00 A.M. to 5:00 P.M., M-F.
02/21/2007 GERRY KOZIOL WWM REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
04/12/2007 DELMA ROBEY OUT TO CUSTOMER Completed
04/12/2007 SUE REEVES REJECT SHELF Completed