Permit Number: T06CM05594
Parcel: 10610005A

Address:
2020 W PRINCE RD

Review Status: Completed

Review Details: RESUBMITTAL - SITE ALL

Permit Number - T06CM05594
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/20/2007 MARTIN BROWN FIRE REVIEW Approv-Cond Relocated fire hydrant needs inspection by Tucson Fire.
09/20/2007 STEVE SHIELDS ZONING HC SITE REVIEW Approved
09/20/2007 STEVE SHIELDS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: American Home Furnishings - Warehouse Expansion
T06CM05594
Site Plan (4th Review)

TRANSMITTAL DATE: September 20, 2007

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This site plan was reviewed for full code compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) due to an expansion of greater then 25% of building/structure area.

2. Zoning was unable to find the recordation information, docket and page, for the Covenant Regarding Development and Use of Real Property

3. D.S. 2-02.2.1.A.7 Based on a determination made by the Zoning Administrator when a parcel borders a street which is shown on The City of Tucson's Major Streets & Routes (MS&R) map all adjacent streets will use the requirements of LUC 3.2.6.5.B to determine the required setbacks. This said, based on the proposed building height of 50'-2" the required setback for Weymouth Street is 50'-2". Depending on the Average Daily Traffic (ADT) and the street cross section for Weymouth Street the required setback is either measured from the back of curb or nearest edge of travel lane. Once the ADT and street cross section for Weymouth Street are provided Zoning can verify if the proposed building meets setbacks.

4. Zoning is willing to provide an over the counter review once all the above comments have been addressed. Please call or email for an appointment.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\site\t06cm05494-4th.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents
10/01/2007 ANDREW CONNOR LANDSCAPE REVIEW Approv-Cond
10/02/2007 ANDREW CONNOR NPPO REVIEW Approved
10/15/2007 PATRICIA GILBERT ENGINEERING REVIEW Approved
10/16/2007 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied Provide the rim elevation of the next upstream sanitary manhole or cleanout. Determine the need for a backwater valve per Section 710.1, UPC 2006, as amended by the City of Tucson.