Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T06CM05467
Parcel: 12107048A

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T06CM05467
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/10/2007 LEERAY HANLY BUILDING-COMMERCIAL REVIEW Denied 1) Architectural and structural pages do not match for roof framing of canopy.

2) Structural analysis is for 14 GA steel as noted on pp S1 but architectural pages indicate 16 GA. Which is it?

3) Structual analysis does not account for new 1 hour rated fire wall. Provide braced frames per the 2006 IRC to support lateral wind loads or provide details and engineering for connecting wall to ramada.

4) Architectural pages consistenly show a built up roof on the ramada/canopy. Structural analysis does not support this.

5) Elevation sheet pp 5 has references to "C.B.U. in 1/8 by 2 frame". What's a CBU? Structural analysis does not support enclosing the ramada

Final Status

Task End Date Reviewer's Name Type of Review Description
11/15/2007 CINDY AGUILAR OUT TO CUSTOMER Completed
11/15/2007 CINDY AGUILAR REJECT SHELF Completed