Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
02/20/2007 | DAVE MANN | FIRE | REVIEW | Denied | Fire sprinklers are required for this dwelling by IFC 503.1 and Appendix B. Indicate on the plans an NFPA 13D system is to be installed and provide flow data. |
02/20/2007 | GERRY KOZIOL | WWM | REVIEW | Denied | 1. CONNECTING TO EXISTING ON-SITE PRIVATE SEWER #PV-2000-024 2. NEEDS WASTEWATER DESIGN REVIEW OF LIFT STATIO - HOWARD WOOLSONCROFT @ 617-8207 - 100 N STONE - 4TH FLOOR |
02/20/2007 | WILDAN | 2ND PARTY REVIEW | REVIEW | Approved | |
03/05/2007 | DAVID RIVERA | ZONING | REVIEW | Approved | |
03/14/2007 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Approved | TO: William Ford, RA, Wilson Builders, LLC. SUBJECT: 240 S Corte Tortuga Vista, Sierra Tortuga Grading Review Resubmittal LOCATION: T14S, R13E, Section 17 REVIEWER: Elizabeth Eberbach ACTIVITY NUMBER: T06BU02456, T06CM05427 Summary: Engineering Division has reviewed the revised grading sheets C1.2, A4.1, A5.1, and A5.2 and soils report, and recommends approval with conditions to the grading permit. GRADING PERMIT CONDITIONS: 1) A Geotechnical Engineering inspection will be required prior to final grading inspection if any approved cut slopes steeper than 1:1(H:V) are constructed, to assure conformance with SAT Laboratory Report dated 10-10-06. Copies of the Geotechnical inspection/evaluation would need to be submitted to DSD Engineering Division Inspector or office prior to scheduling Final Grading Inspection. 2) Prior to picking up permit, assure information is filled out on grading application (green card). I can be reached at 791-5550, ext.2204 if you have questions. Elizabeth Eberbach, PE Civil Engineer Engineering Division Development Services Department |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
04/09/2007 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
04/09/2007 | SUE REEVES | REJECT SHELF | Completed |