Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T06CM05400
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/29/2007 | STANTEC | BUILDING-RESIDENTIAL | REVIEW | Denied | January 25, 2007 To: Steve Long, Acting Building Official City of Tucson Development Services Department 201 N. Stone Avenue, First Floor Tucson, Arizona 85701 Re: Phillips Residence - Addition City of Tucson No. T06CM05400 Stantec Project No. 816-30015-01 (089) Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back-check time, we request that you please provide revised plans and calculations, clouding any changes, along with a written response to each of the noted items indicating the action taken. SCOPE OF REVIEW: The scope of this review covers Architectural, Structural, Plumbing, Mechanical, Model Energy and Electrical codes. All code references are to the 2003 International Residential Code (IRC) except for plumbing, which is to the 2003 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL: There are no general comments to be addressed. ARCHITECTURAL: The following previously made comment has not been addressed. Note and size all roof drains or scuppers on flat-roofed areas [2003 IRC Sec. R903.4 and 2003 IPC Sec. 1106]. The written response indicated that this comment was not applicable. There is a flat roof area; in fact it is absolutely flat with no slope and no drainage. The roof framing plan on Sheet 6 shows a slope direction, however the truss drawing information shows this area to have no slope. This area of the roof needs to have a minimum slope of 1/4” per foot [2003 IRC Sec. R905.9.1]. Again, how does this area of the roof drain if it has no slope? The following previously made comment has not been addressed. Show calculation of attic or rafter ventilation area required and note the location of all vents needed to comply [2003 IRC Sec. R806.2]. The written response indicated “not applicable” because bird boards provided. A calculation still needs to be provided demonstrating that compliance has been achieved. {There are approximately 9.4 square inches (0.065 square feet) of vent area in each bird board assuming 3 holes at 2” diameter each for every 22.5” long bird board. The 1,060 square feet addition therefore requires 7.07 square feet or 109 bird boards; based on the ratio of 1/150. This project adds only 45 bird boards, therefore compliance has not been achieved. Please, do the math on the plans to show compliance and locate the additional upper vents required.} STRUCTURAL: There are no structural comments to be addressed. PLUMBING: There are no plumbing comments to be addressed. MECHANICAL: There are no mechanical comments to be addressed. ELECTRICAL: There are no electrical comments to be addressed. ENERGY: There are no energy comments to be addressed. -End of Review- If you have any questions, please call (520) 750-7474. Sincerely, Stantec Consulting Inc. Joel Svoboda Associate JS:js Attachments: none |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/30/2007 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 01/30/2007 | SUE REEVES | REJECT SHELF | Completed |