Permit Review Detail
Review Status: Completed
Review Details: POST 3RD PARTY REVIEW
Permit Number - T06CM05388
Review Name: POST 3RD PARTY REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/24/2006 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 11/27/2006 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 11/28/2006 | TERRY STEVENS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Terry Stevens Lead Planner PROJECT: T06CM05388 4660 E. Camp Lowell Dr. TI: Restaurant TRANSMITTAL: 11/29/06 COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Provide a copy of the revised Development Plan stamped as a site plan including parking calculations. 2. The Development Plan available on line (BK 28 PG 52) indicates building #4 (A-2) has been approved and parked for 3000 square feet of gross floor area which includes 270 sq. ft. of patio area. The plans submitted indicate 3211 sq. ft. of GFA. The additional GFA appears to be additional patio area near the front entrance being used as seating area. (See sheet A3) This area does not appear to have been approved for use as seating area on the development plan. Clarify. In order to increase the square footage of the GFA above what is approved on the Site/Development plan a revised development plan would be required to be submitted and approved prior to approval of the TI. It does not appear that enough extra parking is being provided in order to increase the square footage of use. 3. The parking calculations provided on sheet C1 are incorrect. See LUC Sec. 3.3.4 Commercial Services Use Group for Food Service. Parking is based on one of two calculations, either 1 space per 100 sq. ft. of GFA or 1 space per 50 sq. ft. of GFA excluding kitchen and storage area. Under the first option based on 3211 GFA 32 parking spaces are required. The second option based on 2019 GFA for the restaurant with out the kitchen area would require 40 parking spaces. Both of the number of parking spaces is in excess of the approved number of parking spaces required for this building on the development plan which is 30. The development plan indicates only one additional parking space being provided above the number of required parking spaces. If this extra parking space is going to be used towards the restaurant use provide documentation of all uses in the development to clearly indicate no other use has already taken the additional parking space. If you have any questions about this transmittal, please call Terry Stevens, (520) 791-5550 ext. 2000. TLS C:\planning\cdrc\DSC\T06CM05388.doc |
| 12/01/2006 | SUE REEVES | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/04/2006 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 12/04/2006 | CINDY AGUILAR | REJECT SHELF | Completed |