Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T06CM05325
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/20/2007 | WILDAN | 2ND PARTY REVIEW | REVIEW | Denied | March 19, 2007 City of Tucson Development Services P.O. Box 27210 Tucson, AZ 85726 RE: Jensen Residence Remodel CITY OF TUCSON LOG NO. T06CM05325 WILLDAN PROJECT NO. 13881-7021 – 2nd REVIEW The initial review for the above project has been completed. This letter contains comments which need to be addressed by written responses to each which indicate any actions taken. In order to facilitate a shorter second review, all corrections and revisions must be made on the original plans and two complete new sets of prints, along with one complete redlined set, must be returned to our office. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets, and that all changes have been highlighted with appropriate revision numbers, revision dates, and “cloud bubbles.” Pen or pencil corrections on final prints are not acceptable. This project has been reviewed for conformance with the 2003 IRC, 1997 UAC, and the 2003 UPC. Any revisions to this plan will require an additional review and approval by Willdan. Should you have questions regarding the comments herein, please contact your plans examiner Antonio Moya. Occupancy Occup. Load Construction Area S.F. Sprinklered Alarms SFR NA V-B 188 No Smoke Special Inspection is required for the following items: N/A The following items are acceptable for deferred submittals: N/A GENERAL COMMENTS: Reviewed and accepted. ARCHITECTURAL COMMENTS: Reviewed and accepted. STRUCTURAL COMMENTS: Reviewed and accepted. PLUMBING COMMENTS: Sheet P-1 Gas appliances shall comply with combustion air requirements. Detail how you will comply. Reference UPC Section 507. COMMENT REMAINS: Not addressed. MECHANICAL COMMENTS: Sheet P-1 Note on plans: “Mechanical shall comply with 2003 IRC Chapters 12-24.” Reference IRC Section M1201.2. COMMENT REMAINS: Not addressed. For gas burning appliances, please provide combustion, ventilation, and dilution air requirements. Reference IRC Section G2407.1. COMMENT REMAINS: Not addressed. Dryer exhaust systems shall be independent of all other systems and shall convey the moisture to the outside of the building. Revise plan. Reference IRC Section M1501.1. COMMENT REMAINS: Not addressed. ELECTRICAL COMMENTS: Reviewed and accepted. ENERGY CODE COMMENTS: Reviewed and accepted. ACCESSIBILITY COMMENTS: Reviewed and accepted. Sincerely, WILLDAN Martin Haeberle, C.B.O. Building Official MAH/tb |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/22/2007 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 03/22/2007 | SUE REEVES | REJECT SHELF | Completed |