Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T06CM05325
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/01/2007 | WILDAN | 2ND PARTY REVIEW | REVIEW | Denied | March 1, 2007 City of Tucson Development Services P.O. Box 27210 Tucson, AZ 85726 RE: Jensen Residence Remodel CITY OF TUCSON LOG NO. T06CM05325 WILLDAN PROJECT NO. 13881-7021 – 1ST REVIEW The initial review for the above project has been completed. This letter contains comments which need to be addressed by written responses to each which indicate any actions taken. In order to facilitate a shorter second review, all corrections and revisions must be made on the original plans and two complete new sets of prints, along with one complete redlined set, must be returned to our office. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets, and that all changes have been highlighted with appropriate revision numbers, revision dates, and “cloud bubbles.” Pen or pencil corrections on final prints are not acceptable. This project has been reviewed for conformance with the 2003 IRC, 1997 UAC, and the 2003 UPC. Any revisions to this plan will require an additional review and approval by Willdan. Should you have questions regarding the comments herein, please contact your plans examiner Antonio Moya. Occupancy Occup. Load Construction Area S.F. Sprinklered Alarms SFR NA V-B 188 No Smoke Special Inspection is required for the following items: N/A The following items are acceptable for deferred submittals: N/A GENERAL COMMENTS: Sheet TS-1 All lettering should be a minimum of 1/8”high. Please revise all lettering that does not meet this standard. Reference the City of Tucson Submittal Requirements. ARCHITECTURAL COMMENTS: Sheet A-1 Provide access to each separate attic and under floor space that exceeds 30SF. Designate locations on the drawings. Openings shall not be less than 22” X 30” for attics. Attic access shall provide a minimum of 30” of headroom and shall be located in a hallway or readily accessible space. Reference IRC Sections R807.1 and R408.3. Indicate all materials used; stucco, concrete block, glass block, roofing system, siding, veneer, etc. Reference IRC Section R703.1. Cross-sections shall be cross-referenced to the floor plan and framing plans. Reference IRC Section R106.1.1. Identify ceiling heights in all areas on floor plan. If sloped ceiling, note average height. Reference IRC Sections R305.1 and R106.1.1. Please provide a cross section to provide full details of work being done. Reference 2003 IRC Section 106.1.1. STRUCTURAL COMMENTS: Sheet A-1 Locate and specify all anchor-bolt spacing on the foundation plan. Reference IRC Section R403.1.6 and Seismic Section R403.1.6.1. Specify lumber grade and species. Specify manufacturer and series on glue-lams and “I” joists. Reference IRC Section R106.1.1. On the floor-framing plan, please provide header size. Reference 2003 IRC Section 106.1.1. PLUMBING COMMENTS: Sheet P-1 Waterline: Provide the total fixture unit demand (based on Tables 6-4 & 7-3 or Tables L-1 & L-2) and the maximum developed length. Reference UPC Section 610. Drainage piping serving fixtures which have flood level rim located below the elevation of the next upstream manhole cover of the public sewer, shall be protected from back-flow of sewage by a backwater valve. Note and specify on plan the location and type. Reference UPC Section 710. (NOT REQUIRED FOR MODEL PLANS UNLESS ACCOMPANIED WITH A SITE PLAN). The City of Tucson has adopted the 2003 Uniform Plumbing Code with local amendments. All plans must reference the 2003 UPC with local amendments in its entirety. Gas appliances shall comply with combustion air requirements. Detail how you will comply. Reference UPC Section 507. MECHANICAL COMMENTS: Sheet P-1 Note on plans: “Mechanical shall comply with 2003 IRC Chapters 12-24.” Reference IRC Section M1201.2. For gas burning appliances, please provide combustion, ventilation, and dilution air requirements. Reference IRC Section G2407.1. Dryer exhaust systems shall be independent of all other systems and shall convey the moisture to the outside of the building. Revise plan. Reference IRC Section M1501.1. ELECTRICAL COMMENTS: Sheet E-1 Show locations of smoke detectors. Reference IRC Sections R313.1 and R313.1.1. ENERGY CODE COMMENTS: Reviewed and accepted. ACCESSIBILITY COMMENTS: Reviewed and accepted. Sincerely, WILLDAN Martin Haeberle, C.B.O. Building Official MAH/tb |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/06/2007 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 03/06/2007 | SUE REEVES | REJECT SHELF | Completed |