Permit Number: T06CM05276
Parcel: 13101071E

Review Status: Completed

Review Details: RESUBMITTAL - SITE ALL

Permit Number - T06CM05276
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/16/2007 DAVE MANN FIRE REVIEW Approved
01/18/2007 JOE LINVILLE LANDSCAPE REVIEW Approved
01/19/2007 JOE LINVILLE NPPO REVIEW Approved Exception.
01/22/2007 STEVE SHIELDS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: VantageWest Credit Union
T06CM05276
Site Plan (2nd Review)

TRANSMITTAL DATE: January 22, 2007

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC).

2. Zoning acknowledges the four vehicle stacking spaces shown on the plan. The stacking spaces shown for the southern most drive-through interfere with the turning radius of the solid waste vehicle. Revise the plan so that the tuning radius does not cross over a required stacking space. Minimum vehicle stacking of four (4) spaces is required to be shown on the plan, this includes the spaces at the window. Demonstrate the required stacking. D.S. 3-05.2.1.C.2.c Additional comments may be forth coming.

3. Per D.S. 2-09.5.2 show the required 60" aisle width on the detail. Also provide a dimension on the plan that shows that the 60" aisle width is maintained between the bicycle rack and the vehicle overhang. The bicycle parking detail does not meet the current development standard D.S. 2-09.0 Supplement 9. The bollard type rack does not provide the two-point support system per D.S. 2-09.2.3 revise the detail. D.S. 2-02.1.A.9

4. Ensure that all changes to the site plan are reflected on the landscape & grading plan..

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 791-5608 ext. 1180.

C:\planning\site\t06cm05276.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents
01/22/2007 STEVE SHIELDS ZONING HC SITE REVIEW Approved
02/01/2007 JASON GREEN ENGINEERING REVIEW Approved DATE: February 2, 2007
SUBJECT: 2222 S Craycroft Rd- 2nd Engineering Review of Site Plan and Grading Plan
TO: Fast Permits
LOCATION: T14S R14E Sec23, Ward 5
REVIEWERS: Jason Green, CFM
ACTIVITY: T06CM05276 (site plan) and T06BU02417 (grading plan)


SUMMARY: Engineering Division of Development Services Department has received and reviewed the revised site plan (T06CM05276), revised grading plan (T06BU02417), drainage report (prepared by CMG Drainage Engineering, Inc.) with attached addendum, geotechnical report addendum (prepared by Western Technologies, Inc), and revised Stormwater Prevention Pollution Plan (SWPPP), for the above referenced property. Engineering Division recommends conditional approval of the site plan and grading plan at this time. The following item needs to be addressed prior to stamp approval of the site plan or grading plan:


SITE PLAN COMMENTS:

1) DS Sec.6-01.4.1: Revise the site plan to show that the maneuverability of the solid waste vehicle is not obstructed by the vehicle stacking spaces required for the drive thru window. The maneuverability shown in the pdf attachment sent to Steve Shields, Zoning Division is acceptable. Provide the change to the proposed site plan and grading plan prior to approval.

2) Over the counter stamp approval is required for the site and grading plan sheets. Provide the applicable sheets to show maneuverability for the solid waste vehicle.


GENERAL COMMENTS:

Please provide revised site plan and grading plan sheets that address the comment provided above. For expedite purposes the site plan and grading plan can be reviewed over the counter for stamp approval.

If you have any questions, or to schedule an appointment, I can be reached at 791-5550, extension 1189.



Jason Green, CFM
Senior Engineer Associate
Engineering Division
Development Services
02/01/2007 JASON GREEN ENGINEERING REVIEW Approved Site plan and grading plan must still be stamped approved prior to issuing permits. Over the counter review is required.
02/01/2007 JASON GREEN ENGINEERING REVIEW Approved DATE: February 8, 2007
SUBJECT: 2222 S Craycroft Rd- 2nd Engineering Review of Site Plan and Grading Plan
TO: Fast Permits
LOCATION: T14S R14E Sec23, Ward 5
REVIEWERS: Jason Green, CFM
ACTIVITY: T06CM05276 (site plan) and T06BU02417 (grading plan)


SUMMARY: Engineering Division of Development Services Department has received and reviewed the revised site plan (T06CM05276), revised grading plan (T06BU02417), drainage report (prepared by CMG Drainage Engineering, Inc.) with attached addendum, geotechnical report addendum (prepared by Western Technologies, Inc), and revised Stormwater Prevention Pollution Plan (SWPPP), for the above referenced property. Engineering Division recommends approval of the site plan and grading plan at this time.

If you have any questions I can be reached at 791-5550, extension 1189.



Jason Green, CFM
Senior Engineer Associate
Engineering Division
Development Services