Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T06CM05268
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/04/2006 | DAVE MANN | FIRE | REVIEW | Denied | 1. Additional fire hydrants shall be provided by the developer as required by the fire code in accordance with C.O.T. Standards. |
| 12/05/2006 | STEVE SHIELDS | ZONING HC SITE | REVIEW | Denied | See Zoning Comments |
| 12/06/2006 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: GLENN VERDE CONDOMINIUMS T06CM05268 Site Plan (2nd Review) TRANSMITTAL DATE: December 6, 2006 COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.), Land Use Code (LUC) & ICC/ANSI A117.1-2003 2. Under the assumption that all units will have a 2nd story addition this plan is reviewed for full code compliance due to a greater then 25% building expansion. Additional comments may be forth coming. 3. The provided elevations are not to scale and do not have enough information to determine setbacks. These elevations appear to be front elevations of the proposed project, not the rear elevations. The elevation of concern is the rear elevation, the elevation that faces the property lines. The provided elevation does not show the existing porches. Also the partial elevation shows the second story setback from the existing, where does this occur and what is the dimension of this setback. Provide elevations for the proposed 2nd floor additions. Additional comments may be forth coming. 4. Zoning acknowledges that an error was made in this comment. The error in dimension for the property line was in the east west dimensions, which have been corrected. The north south dimensions were correct as shown on the last plan. Please correct the revise the north south dimensions to match what is shown on the attached plat. The lot dimensions do not match what is shown on the 1980 plat or the Assessors Record map. The north and south dimensions have a difference of 10', clarify. Also the east dimension and bearing text are screened, please revise so that the dimension and bearing are not screened. D.S. 2-02.2.1.A.5 5. The setback data shown under the "LAND USE CODE DATA:" is still incorrect. Per LUC Sec. 3.2.6.5.B the required street setback is 21 or the height of the building wall, not 2/3 Height, which ever is greatest, measured from the back of future curb not the property line. The required setback to the interior (east, west & south) property line is 10' or ¾ the Height of the wall, which ever is greatest measured from design grade. Based on the elevations provided, the height shown is from the finished floor. This said zoning adds a minimum of six (6) inches to that height which means the required setback would be sixteen feet two inch. This maybe an issue along the east property line. Provide a dimension to design grade for the elevations. A setback dimension to the existing porches is required. The street setback is 21 or the height of the building wall which ever is greatest, measured from the back of future curb not the property line. Revise the plan to show the future curb and the setback measured from back of future curb. LUC 3.2.6.5 Per the LUC 2.3.5 R2 Residence Zone, Development Designator "K" the required setback to the rear and side yards is 10' or ¾ the Height of the wall. Based on the 21 feet designated under the "LAND USE CODE DATA: #6" the minimum setback to the side and rear property line is 15.75'. D.S. 2-02.2.1.A.7 6. Provide a space depth & curb length dimension, see LUC Sec. 3.3.7.2 "C Space Depth and E Curb Length" for the angled parking. The one way PAAL, which connects to the fire lane near PS 15, 23 & 24 cuts of the driveway access to PS 15, revise plan. The horizontal dimension provide at the angle parking on the north side of the southern buildings calls out "10 SPACES @ 9'=130', There are only 9 parking spaces shown. Provide a fully dimensioned layout of the parking, this includes a dimension for the angle of the angled parking see LUC 3.3.7.2. D.S. 2-02.2.1.A.8 7. Zoning acknowledges that a DSMR has been applied for. The one-way PAALs which run around the east and west ends of the south buildings require a minimum of a 2' setback from the property line. D.S. 3-05.2.2.B.3 8. Zoning acknowledges that a DSMR has been applied for. The one-way PAALs which run around the east and west ends of the south buildings require a five foot pedestrian refuge area between the PAAL and an enclosed structure. D.S. 3-05.2.2.B.1 9. The wheel stops shown along the south parking are not shown correctly. The wheel stops should be 2'-6" from the front of the parking spaces D.S. 3-05.2.3.2. Also wheel stops are required at the angle parking shown on the north side of the southern most buildings. Barriers are required to prevent parked vehicles from damaging adjacent landscaping or overhanging adjacent sidewalk areas or unpaved areas on or off site and to prevent vehicles from driving onto unimproved portions of the site. Curb stops will be required at all proposed parking spaces or demonstrate how the overhang will not effect any of the above items. D.S. 3-05.2.3.C. 10. The detail is still incorrect, see redline. The 60" aisle width cannot be part of the pedestrian way. Revise detail. Under the "LAND USE CODE DATA: #8" Bicycle parking proposed = 2-Class1 & 2-Class 2. There is a detail for Class 2 bicycle but not for Class 1. For your information Per LUC 3.3.7.8.A Class 2 bicycle parking may be substituted for Class 1 when less then 50 parking spaces are provided. The bicycle parking detail does not meet the current development standards. The bollard type rack does not provide the two-point support system D.S. 2-09.2.3 the detail needs to provide the information required in D.S. 2-02.2.1.A.9 demonstrate how the proposed location meets the requirements of DS 2-09.3.2 and 2-09.4.1 & 4.4. Signage will be required. 11. The SVT's shown are not correct, see engineering comments. Provide existing and future sight visibility triangles. D.S. 2-02.2.1.A.10. 12. Demonstrate how the continuous pedestrian circulation path and accessible route works with the covered parking spaces PS 9 & 10. Is there any conflict with supporting structures? All access across the proposed driveways will be stripped, provide dimension for the width. The stripped area across the proposed driveways cannot be part of the proposed wedge curb. There needs to be an accessible ramp at the crosswalk just south of PS3. The crosswalk as shown at the southwest corner of the drive at PS 15, 23 & 24 is a safety issue and needs to be relocated, see redline. A continuous pedestrian circulation path and accessible route are required to connect to the pedestrian circulation path located in the adjacent street. 2-08.3.0 This circulation path may not be located between the vehicle parking space (the northern most proposed parking spaces located new the north property line) and the PAAL providing access to the space. Provide at least one continuous pedestrian circulation path and accessible route to the sidewalk along Glenn. D.S. 2-02.2.1.A.12 13. The are a couple of 5' easements called out along the along the east and west property. The west easement is shown graphically but no recordation information is provided. The east easement is not shown graphically and no recordation information is provided. If applicable all easements of record must be graphically shown on the plan together with recording docket and page reference. D.S. 2-02.2.1.A.20 14. Per your response zoning can not verify existing lighting on bottom of site plan sheet 1 none is shown, clarify. If applicable provide existing and proposed lighting layout and type. D.S. 2-02.2.1.A.25 15. The parking calculation is incorrect. Pre LUC Sec 3.3.4 RESIDENTIAL USE GROUP, Family dwelling: Mobile Home Dwelling, Multifamily Dwellings 0-70 units/acre, Studio, more the 400 sq. ft. GFA, and One Bedroom requires 1.5 parking spaces per dwelling unit. Also the proposed spaces shows 47 but there are only 46 spaces on site. Provide the number of proposed and provided vehicle parking spaces. D.S. 2-02.2.2.A.4 16. Under the bicycle parking calculation provide the proposed and provided bicycle parking spaces D.S. 2-02.2.2.A.4 17. This comment has not been addressed. Provide the percentage of building expansion calculation. D.S. 2-02.2.2.A.6 18. Zoning is waiting on a determination from the City of Tucson's Attorney in regards to the addition of the second floor and weather this will require a revised plat. A re-plat will be required. 19. This comment has not been addressed. Add the existing Map & Plat number to the title block. 20. The title block has been revised to read "GLENN VERDE TOWNHOMES" instead of "GLENN VERDE CONDOMINIUMS", please clarify what this project is. If this is a Townhomes project a Residential Cluster Project (RCP) is required. Since this site is less then five acres the RCP would need to be processed as a Special Exception to the Land Use Code. Along with the Special Exception process per LUC Sec. 3.6.1.7 a tentative plat/final plat is required. 21. Additional comments could be forthcoming depending on how each comment has been addressed. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 791-5608 ext. 1180. C:\planning\site\t06cm05268.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents |
| 12/14/2006 | ANDREW CONNOR | NPPO | REVIEW | Denied | Submit Application for Exception; include acceptable documentation, which clearly indicates that the project will not impact Protected Native Plants. Revise application to indicate that protected native plants will not be substantially impacted by development on this site. Additional comments may apply upon inspection of site. |
| 12/14/2006 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1. Submit a landscape plan per DS 2-07.0. to verify that entire site meets current minimum requirements. Indicate all improvements. All elements of landscape plan must be graphically shown including all plant materials for required coverage and screening. Review all comments enclosed and respond accordingly. 2. Fifty (50) percent or more of the street landscape border area must have shrubs and vegetative ground cover per LUC 3.7.2.4. Show graphically the locations of individual plants 3. Indicate square footage of all landscaped areas and calculation of the percentage of vegetative coverage per DS 2-07.2.2.2.g 4. A 30" continuous screen along street frontages for vehicle use area must be provided per LUC Table 3.7.2-I. Show graphically the locations of screening elements. 5. The planting plan and layout calculations will include the following Information: § Both the proper and common name of each type of plant material must be listed. § Locations, size, and name of all existing vegetation to remain in place. § Material and areas of inert ground cover. All disturbed areas including adjacent right of ways shall be treated with ground cover such as decomposed granite to help reduce dust pollution per LUC 3.7.2.7. Indicate treatment for landscaped areas. 6. Within vehicular use areas, one (1) canopy tree is required for each 10 motor vehicle parking spaces and every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk) per LUC 3.7.2.3.A.1.a. Correctly identify and place canopy trees within vehicle use are 7. Landscaping along parking lots where plants are susceptible to injury by vehicular traffic must be protected by appropriate means, such as curbs, bollards, or low walls per LUC 3.7.2.3.B. Indicate protection for landscaping 8. Submit Application for Exception; include acceptable documentation, which clearly indicates that the project will not impact Protected Native Plants. Revise application to indicate that protected native plants will not be substantially impacted by development on this site. Additional comments may apply upon inspection of site. 9. Landscape plan shall include irrigation specification design and layout per DS 2-06.5.4.A & DS 2-06.5.4.B including source of irrigation, sleeves for driveways and sidewalks, locations of valves, low-flow bubblers or drip irrigation. Include irrigation design 10. Additional comments may apply. |
| 12/22/2006 | PATRICIA GILBERT | ENGINEERING | REVIEW | Denied | DATE: January 5, 2007 ACTIVITY NUMBER: T06CM05268 PROJECT NAME: Glenn Verde Condominiums Site Plan PROJECT ADDRESS: 3422 East Glenn Street PROJECT REVIEWER: Patricia Gilbert, Engineering Associate The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed. RESUBMITTAL REQUIRED: SITE PLAN APPROVED: DRAINAGE STATEMENT 1. Identify the street centerline of Glenn Street with an appropriate symbol. 2. All lettering and dimensions will be the equivalent of twelve point or greater in size. The purpose of this requirement is to assure that the lettering is legible when reproduced or microfilmed for record keeping purposes. Revise the font size on sheet 2 to be at minimum 12 point. DS 2-03.2.1.A. The above comment has not been addressed. The details are now provided on sheet 4 and the font size has not been revised. Revise the detail sheet to provide the correct font size. See redlines. 3. Provide existing and future sight visibility triangles. DS 2-01.2.1.A.10., DS 3-01.5.0. The above comment is from the first review and has not been addressed correctly. The stem of the SVT is 20' and only a 10' stem has been provided. Correct the plan to show a 20' stem. It is also not clear if the SVT is the existing SVT or the existing and future SVT. This is based on if the existing ROW is also the future. The SVT must be label either "existing" or "existing/future." Clarify in detail in the response letter and if necessary revise the site plan. 4. Provide drainage patterns and existing finish grades on the plan view. DS 2-02.2.1.A.16. The above comment is from the first review and has not been fully addressed. It appears a drainage arrow has been provided (see redlines). However the arrow is not identified, so it is not clear if the arrow is depicting drainage direction or something else. It is highly recommended to provide a legend with any symbols that is provided on the plan. Identify the arrow and if it is not depicting drainage, provide the requested drainage information. 5. Show on the site plan the off site to on site and on site to off site existing 100 year discharge concentration points discussed in the drainage statement. It must be clear on the site plan where the stormwater is coming from and where the stormwater is going. SMDDFM 2.3.1.6.A. The above comment is from the first review and has not been entirely addressed. It is acknowledged that the offsite drainage (20 cfs) from the southeast has been shown on the plan. The drainage statement discusses a total of 18 wall openings to allow the off site flow to enter the site. The location of the wall opening must be shown on the plan. Provide this information on the plan. Additionally the 12 cfs generated on site must also be shown on the plan. Provide on the plan the location of where onsite flow exits the property. 6. It is acknowledged that the structures are existing however the parking lot is being improved. Is the entire parking being regraded? Or simply resurfaced? This must be clear on the site plan. Revise accordingly. If cut and fill quantities change revise quantities on the site plan. DS 2-02.2.1.A.17. The response to this comment was, "Refer to revised info on sheet 1." It still is not clear on the plan if the asphalt is being replaced. Keynote number 5 depicts asphalt concrete. For clarity indicate in keynote 5 if the asphalt is existing or new. 7. Grading, hydrology, landscape islands and borders are to be integrated in effort to make maximum use of stormwater runoff for supplemental irrigation purposes. Landscape islands and borders must provide water harvesting from the vehicle use area and the rooftops. Small curb opening must be provided to accept the surface stormwater. Revise the site plan to meet this criteria. LUC 3.7.4.3.B. The response to the above comment indicated this comment has been adressed with use of curb cuts and wall openings. It is not clear where the location of the curb cuts and wall openings are located. The plan must clearly show how stormwater is entering landscape borders to meet the above referenced criteria. It is acknowledged keynote 10 indicates a toe down curb. It is not clear if this is a curb cut for stormwater to enter a landscape area or driveway. It is acknowledged the landscape plans indicates a Palm tree in this general area. Is this where the curb cut is located? The leader points to a sidewalk. Is the intent to provide a sidewalk scupper to allow stormwater to offer supplemental irrigation to the palm trees? Stormwater should also be directed towards the required street and interior landscape border. Revise the site plan to clearly show the intent and provide a detailed response in the response letter. 8. Provide the recordation data (book and page) for Glenn road. Second request. DS 2-02.2.1.A.18. 9. The entrance and exit drives provided on the proposed development does not meet Transportation Access Management Guidelines (TAMG). Provide written approval from Traffic Engineering, contact Jose Ortiz P.E. at 837-6730. 10. Clarify if the current ROW is built out to the future ROW. Provide appropriate labels (i.e. existing and future ROW, sidewalk, etc). DS 2-02.2.1.A.19. 11. Indicate in keynote 19 if the 6' sidewalk is existing or proposed. DS 2-02.2.1.A.21. 12. Provide a dimension from street centerline to the existing ROW location. (see comment number 10) DS 2-02.2.1.A.21. 13. Indicate on the site plan the exact locations of the wall openings as discussed in the drainage statement. This comment has not been addressed. Second request. See above comment 8. SMDDFM 12.5. 14. Provide topographic contours at intervals not exceeding 2 feet, spot elevations and Bench Mark based on the City of Tucson datum, include the City of Tucson field book and page number. DS 2-02.2.1.A.23. It is acknowledged the datum has been provided. However spot elevations are not identified on the plan and the response letter indicates spot elevations have been provided. Provide either contours or spot elevations on the plan. Provide symbol and identification in the legend. 15. A 5' pedestrian refuge area with a 4' sidewalk is required when a structure is adjacent to a PAAL. This must be maintained throughout the entire site. The structures to the south adjacent to the 12' one way PAAL does not provide the 5' pedestrian area. Revise plan as necessary. DS 3-05.2.2.B.1., Figure 1 and DS 2-08.4.1.B. It is acknowledged the above comment is going possibly be modified with a DSMR. If this is approved provide the DSMR case number and any conditions of the approval. 16. A minimum distance of 2' must be maintained between a PAAL and a wall, screen or other obstruction. This requirement is not met where the back southern structures are adjacent to the 12' one way PAAL. The one way PAAL is adjacent to the property line. This will not be accepted. Revise the site plan to meet this requirement. DS 3-05.2.2.B.3. It is acknowledged the above comment is going possibly be modified with a DSMR. If this is approved provide the DSMR case number and any conditions of the approval. 17. Keynote 10 indicates a toe down curb. The PAAL detail on sheet 2 depicts a wedged curb. Revise keynote 10 to indicate wedged curb. This is the second request. 18. Provide a cross section from the south buildings, through the parking area to the common area. This is the second request. 19. Provide a cross section for the west and east one way PAALs. This is the second request. 20. It must be clear if this project is a townhomes or condominiums. The development process is different for each type of development. Please refer to the zoning comment addressing this. 21. Additional comments could be forthcoming depending on how each comment has been addressed. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/08/2007 | FSANCHE1 | OUT TO CUSTOMER | Completed |