Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL-BLDG/FIRE/ZONING/ENG
Permit Number - T06CM05178
Review Name: COMMERCIAL-BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/28/2006 | DOUG LAAKSO | BUILDING-COMMERCIAL | REVIEW | Approv-Cond | S1. IRC NOT ACCEPTABLE FOR IBC PROJECT , REVISE NOTES AND REFERENCES. S2. CLARIFY CONNECTIONS MASONRY TO WOOD TO PROVIDE SEISMIC CONNECTION FOR ANCHORAGE PER IBC SECTION 280 POUNCS PER LIN FOOT AND NAILING FROM ROOF SHEATHING TO MASONRY THROUGH BLOCKING , TOP PLATE AND BOLTING TO MASONRY. |
| 09/28/2006 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 09/28/2006 | SUZANNE BOHNET | ENGINEERING | REVIEW | Approved | |
| 09/28/2006 | DAVE MANN | FIRE | REVIEW | Approved | |
| 09/28/2006 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
| 09/29/2006 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/29/2006 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |