Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T06CM05126
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/26/2007 | WILDAN | 2ND PARTY REVIEW | REVIEW | Denied | March 23, 2007 City of Tucson Development Services 201 N. Stone Avenue Tucson, AZ 85701 RE: CARPENTER RESIDENCE ADDITION – 2nd REVIEW CITY OF TUCSON LOG NO. T06CM05126 WILLDAN PROJECT NO. 13881-7011 The initial review for the above project has been completed. This letter contains comments which need to be addressed by written responses to each which indicate any actions taken. In order to facilitate a shorter second review, all corrections and revisions must be made on the original plans and two complete new sets of prints, along with one complete redlined set, must be returned to our office. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets, and that all changes have been highlighted with appropriate revision numbers, revision dates, and “cloud bubbles.” Pen or pencil corrections on final prints are not acceptable. This project has been reviewed for conformance with the 2003 IRC, 1997 UAC, 2003 IMC, 2003 IECC, 2002 NEC codes with local modifications, and the 2003 UPC with State of Arizona Amendments. Any revisions to this plan will require an additional review and approval by Willdan. Should you have questions regarding the comments herein, please contact your plans examiner Antonio Moya. Occupancy Occup. Load Construction Area S.F. Sprinklered Alarms Dwelling (exist.) Porch (exist.) New Dwelling New Porch N/A V-B 1,072 135 586 278 No Smoke Special Inspections Required: N/A Acceptable Deferred Submittal Items: Pre-manufactured “I” joist drawings. GENERAL COMMENTS: All Sheets All text shall be capitalized and no smaller than 1/8”. Reference IRC Section R106.1.1 and City of Tucson Submittal Requirements. COMMENT REMAINS: Revise all sheets that need it.. Sheet 2 List the square footage for all the following area separately on the drawings: a. Covered porches (existing and new) b. Living Space (existing and new) Reference IRC Section R106.1.1. COMMENT REMAINS: Not addressed. ARCHITECTURAL COMMENTS: Reviewed and accepted. STRUCTURAL COMMENTS: Sheet 7 Exterior corner framing must comply with IRC Figure R602.10.5 for continuous structural panel sheathing at exterior walls. Provide details on the plan. COMMENT REMAINS: Not addressed. PLUMBING COMMENTS: Sheet 8 Show all required clean-outs on the plumbing isometric. Reference the City of Tucson Submittal Requirements and 2003 UPC Section 707. COMMENT REMAINS: Not addressed. MECHANICAL COMMENTS: Sheet 10 Show exhaust fan locations and exhaust duct terminations the laundry room in lieu of operable windows. Reference IRC Section R303.3. COMMENT REMAINS: Not addressed. For the gas burning water heater, please provide combustion, ventilation, and dilution air requirements. Reference IRC Section G2407.1. COMMENT REMAINS: Please provide full details how combustion air will be obtained. ELECTRICAL COMMENTS: Sheet 9 Please provide cut sheets and calculations for all exterior lighting fixtures. Reference City of Tucson Outdoor Lighting Code. COMMENT REMAINS: Not addressed. Cross-reference exterior lighting fixtures on the plans with the cut sheets and calculations submitted. Reference City of Tucson Submittal Requirements. COMMENT REMAINS: Not addressed. ENERGY CODE COMMENTS: Reviewed and accepted. Sincerely, WILLDAN Martin Haeberle, C.B.O. Building Official MAH/tb |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/26/2007 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 03/26/2007 | SUE REEVES | REJECT SHELF | Completed |