Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T06CM05073
Parcel: 10707018B

Address:
1102 W GRANT RD

Review Status: Completed

Review Details: RESUBMITTAL - SITE ALL

Permit Number - T06CM05073
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/05/2007 DAVE MANN FIRE REVIEW Denied Fire hydrants shall be located within 300' of all parts of all stuctures, with no obstructions that may impede laying of fire hose. Indicate locations (with dimensions if necessary).
Gate (keynote 5) shall allow 20' wide unobstucted access. (No center pole). Fire Department lock box required.
02/08/2007 STEVE SHIELDS ZONING HC SITE REVIEW Approved
02/08/2007 STEVE SHIELDS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: FARMER JOHN SELF STORAGE
T06CM05073
Site Plan (2nd Review)

TRANSMITTAL DATE: February 8, 2007

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC).

2. This comment has not been fully addressed. The location of a pole mounted sign cannot encroach into the overhang area of the vehicle parking space. Zoning recommends that a wall mounted sign be used. Zoning is willing to provide an over the counter review once the corrections are made, call or email for an appointment. The location of the handicapped parking sign cannot reduce the width of the sidewalk to less then 4', provide a dimension which verifies the width of the sidewalk or relocate the sign. D.S. 2-08.5.1 Provide a detail for the handicapped sign.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 791-5608 ext. 1180.

C:\planning\site\t06cm05073-2nd.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents
02/15/2007 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. A street landscape border, per Sec. 3.7.2.4 of the LUC, is a landscape area with a minimum width of ten (10) feet, running the full length of the street property line(s) bounding the site except for points of ingress-egress. On streets designated as Major Streets and Routes (MS&R), the street landscape border is measured from the MS&R right-of-way line as determined by LUC 2.8.3.4.

2. Street landscape borders shall be located entirely on site, except that, if approved by the City Engineer or designee. Up to five (5) feet of the required ten (10) foot width be placed within the adjacent right-of-way area or within the Major Streets and Routes (MS&R) right-of-way area on MS&R streets.

3. Whether or not required by this Division, screens along a street frontage must be located on the development side of the street landscape border so that they do not obstruct the view of the street landscape border from the street per LUC 3.7.3.2.B

4. Fifty (50) percent or more of the street landscape border area must have shrubs and vegetative ground cover per LUC 3.7.2.4

5. Indicate square footage of all landscaped areas and calculation of the percentage of vegetative coverage per DS 2-07.2.2.2.g

6. One (1) canopy tree must be provided for every thirty-three (33) linear feet of landscape border per LUC 3.7.2.4. Required trees must be visible from street.

7. Include with re-submittal approval documentation. Indicate on the lower right hand corner of the site plan, the variance case number, date of approval, and any conditions imposed.

8. Additional comments may apply.
02/16/2007 ANDREW CONNOR NPPO REVIEW Approved
03/01/2007 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Show the sizes of the water meters and backflow prevention assemblies.
2. Show the invert and rim elevations of all of the sanitary sewer manholes and cleanouts, along with the Pima County Wastewater Management Department (PCWMD) reference numbers.
3. Show the location and size of the existing connection to the Pima County sanitary sewer system
03/09/2007 SUZANNE BOHNET ENGINEERING REVIEW Denied DATE: March 15, 2007
FROM: Suzanne Bohnet, CFM
Engineering Division

SUBJECT: 1102 W. Grant Rd.
Farmer John Self-Storage
Site Plan T06CM05073 (Second Review)

RESUBMITTAL REQUIRED: Site Plan, Grading Plan and Drainage Report.

The Site Plan, Grading Plan and Drainage Report cannot be approved as submitted. Please include a response letter to the comments below along with the corrected copies of the Site Plan and Grading Plan with your next submittal. In addition, provide two copies of the Drainage Report and Geotechnical Engineering Report with the next submittal, 4 copies of the Grading Plan and 3 copies of the Stormwater Pollution Prevention Plan.

Site Plan:
1. Confirm that truncated domes are to be installed for the handicapped parking spaces located on the east side of the existing building. From the Site Plan, it appears that truncated domes are shown on the side ramps but not at the interface of the striped area in the parking lot and the flush sidewalk.

Grading Plan:
1. Provide the water surface elevation of the three retention/detention basins in order to verify the finished floor elevation of adjacent buildings has the required one-foot freeboard.
2. Add a note stating: "All landscape areas are to be depressed 6" for water-harvesting purposes".
3. Add a note regarding basin inspection and maintenance per the Standards Manual for Drainage Design and Floodplain Management (SMDDFM) 14.3.
4. Add a note referencing the Geotechnical Engineering Report performed by LMT Engineering Inc. agreeing to abide by the recommendations and observations for grading activities.
5. Provide an access ramp to the large northwest retention/detention basin for maintenance purposes, the slope of which is not exceed 15% (SMDDFM 14.3.4).
6. Provide labels on the existing contour and the contour interval next to the north arrow and scale.

Drainage Report:
1. Provide a detailed Basin Maintenance Checklist and Schedule in the Drainage Report (SMDDFM 2.3.1.2.E.1).

Stormwater Pollution Prevention Plan:
1. The Stormwater Pollution Prevention Plan submitted is conditionally approved. Provide a copy of the Notice of Intent prior to Grading Permit issuance.

Please do not hesitate to contact me with any questions.

Thank you,
Suzanne Bohnet, CFM
Engineering Associate
(520) 791-5550 x1188 office
Suzanne.Bohnet@tucsonaz.gov

Final Status

Task End Date Reviewer's Name Type of Review Description
03/23/2007 FSANCHE1 OUT TO CUSTOMER Completed
03/23/2007 SUE REEVES REJECT SHELF Completed