Permit Number: T06CM04933
Parcel: 133380920

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T06CM04933
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/15/2007 LINHART PETERSEN POERS ASSOC. 2ND PARTY REVIEW REVIEW Denied May 9, 2007 CITY OF TUCSON - SECOND CHECK
Tucson Appl. No. T06CM04933
Bureau Veritas Job No. 01006-161080
Mr. Juan Heredia
10301 E. Calle Magdalena
Tucson, AZ 85705


Re: Plan Review: Heredia Residence
Address: 10301 E. Calle Magdalena

Dear Mr. Heredia:

Bureau Veritas North America has completed a review of the following documents on behalf of the City of Tucson:

Plans: One (1) set of plans (13 sheets, 1 through 13) no dates, no stamps.

Structural Calculations: None submitted with this review.

Soils Letter/Report: None submitted with this review.

Miscellaneous: One (1) copy of amended NPPO Report for NOUS.


These documents were reviewed only for their conformance to the provisions of the 2003 International Building Codes (i.e., State of Arizona and Tucson amended 2003 IRC, 2003 IMC, 2002 NEC and 2003 IPC).

Please submit an itemized response letter and required number of complete and revised documents with all revisions clouded.



Sincerely,

BUREAU VERITAS North America


Randy McCoy
ICC Plans Examiner








SK:pc F:\Tucson\01006-1610080pc1.doc
enclosures


A. The following plan review comments are based on the City of Tucson Building Regulations and referred to the 2003 International Residential Code.

B. Please respond in writing to each comment by marking the attached comment list or creating a response letter. Indicate which detail, specification, or calculation shows the requested information. Your complete and clear responses will expedite the re-check and hopefully, approval of this project. Thank you for your assistance.

C. These plan review comments are based on building code items only. If site-related comments are applicable to this project, they will be generated by others (e.g., County Engineering, Public Works, Health, etc.).



STAIR REQUIREMENTS:


Spiral stairways are permitted, provided the minimum width shall be 26 inches with each tread having a 7.5 in. minimum tread width depth at 12 in. from the narrower edge. All treads shall be identical, and the rise shall be no more than 9 ½ inches. Minimum headroom of 6’6” shall be provided. R311.5.8.1.

Two or more stair risers shall have at least one handrail. Handrails shall be provided on at least one side of the stairs, be continuous the full length of the stairs, and have minimum and maximum heights of 34 inches and 36 inches, respectively, measure vertically from the nosing of the treads, The handgrip portion of the handrails shall have a circular cross section of 1 ¼ inches minimum to 2 5/8 inches maximum radius of 1/8 inch. IRC Section R315.

The minimum height of guards shall be not less than 36 inches. Openings in guards shall have intermediate rails or ornamental closure that do not allow passage of a sphere 4 inches in diameter, IRC Section R315.2.




FRAMING PLAN:


Indicate all braced wall panel locations. Specify the methods of bracing to be used. A sealed lateral analysis, prepared by an Arizona Registrant, will be required of the bracing does not comply with the conventional provisions. IRC Section R602.

Specify design criteria: roof live and dead loads. IRC Section R301.


Truss Systems: Trusses can be submitted as a “Deferred Submittal”. However, they must be submitted and approved prior to their fabrication. Approved truss calcs. must be provided for framing inspection.

Provide complete truss calculations and truss layout plan. Truss designs submitted must include all types and be designed for the loading conditions, span, slope, and spacing designated on the framing plan.

Truss calculations must be signed, dated and sealed by an Engineer who is registered in the State of Arizona.

The seal on the truss calculations shall be dates within the latest adopted IRC.

All truss calculations shall be cross-referenced to the truss layout or the roof and floor framing plans.

Specify all hangers used to hang trusses from girder trusses, wall, or other locations. IRC Section R802 & ANSI-TPI 1995.


PLUMBING COMMENTS:.

Provide a gas isometric with length of line (horizontal and vertical) to each appliance, BTU demand of each appliance, size of each branch, total demand and size of the meter.


If you have any questions regarding the above comments, please contact Shelley Knuffke at (520) 576-8400 between 8:00 A.M. to 5:00 P.M., M-F.
05/22/2007 STEVE SHIELDS ZONING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
11/14/2007 GERARDO BONILLA OUT TO CUSTOMER Completed
11/14/2007 GERARDO BONILLA REJECT SHELF Completed