Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T06CM04900
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/05/2007 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 02/14/2007 | DANIEL RUSCH | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS for Activity # T06CM04900 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2003 International Residential Code, 2003 International Energy Conservation Code, and Arizona State amendments to the 2003 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: All corrections and revisions shall be made on original tracings or finished reproducible set. Return this set and a copy along with a set of the first submission. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. Construction drawing guidelines are available from the residential desk of the Development Services Division. As of 9-02-04 the City of Tucson has adopted the 2003 IRC with the exception of the plumbing portion which has been replaced with the 2003 UPC with amendments. All plans should reference these codes. See this site for all adopted amendments: http://www.tucsonaz.gov/dsd/Codes___Ordinances/Building_Codes/building_codes.html Provide a note for: Underground facility tracer wires per DSD Memo, 10/24/2005. SECTIONS - DETAILS - MISC. NOTES: 1. Sheet A1-1 does not show new construction. Consider removing this sheet as inappropriate to scope. 2. Clarify the roof ledger size. The plan on S-1 & detail 2/S-3 shows 3x10, but details 7&8/S-3 shows 2x. PLUMBING PLANS: 1. Provide the location of the new water heater referenced at note #19, UPC 508.27. 2. The water fixture units for the additional hose bibbs may be reduced from 2.5 to 1 each, per 2003 UPC Table 6-4. 3. Provide a 1-1/4" water line from the meter to the water heater or first bath room group as required by 2003 UPC Table 6-5. INTERNATIONAL ENERGY CONSERVATION CODE: 1. The simplified prescribed energy values for glazing U=0.65, ceiling R=30 and walls R=13 complies with energy requirements 2003 IECC w/ local amendments if glazing does not exceed 15% of exterior wall area. Show the "U" factors of the windows and doors on the plans as well as the solar heat gain coefficient SHGC minimum value of 0.40. If you have any questions, please contact your assigned plans examiner Ken Van Karsen at 791-5550, extension 1112. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/08/2007 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 03/08/2007 | SUE REEVES | REJECT SHELF | Completed |