Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T06CM04893
Review Name: RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
12/20/2006 | WILDAN | 2ND PARTY REVIEW | REVIEW | Denied | December 19, 2006 City of Tucson Development Services 201 N. Stone Avenue Tucson, AZ 85701 RE: MENLO PARK LOT 24 – 2nd REVIEW CITY OF TUCSON LOG NO. T06CM04893 WILLDAN PROJECT NO. 13881-6052 The second review for the above project has been completed. This letter contains comments which need to be addressed by written responses to each which indicate any actions taken. In order to facilitate a shorter third review, all corrections and revisions must be made on the original plans and two complete new sets of prints, along with one complete redlined set, must be returned to our office. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets, and that all changes have been highlighted with appropriate revision numbers, revision dates, and “cloud bubbles.” Pen or pencil corrections on final prints are not acceptable. This project has been reviewed for conformance with the 2003 IRC, 1997 UAC, 2003 IMC, 2003 IECC, 2002 NEC codes with local modifications, and the 2003 UPC with State of Arizona Amendments. Any revisions to this plan will require an additional review and approval by Willdan. Should you have questions regarding the comments herein, please contact your plans examiner Antonio Moya. Occupancy Occup. Load Construction Area S.F. Sprinklered Alarms SFR Garage N/A III-B 2726 550 No Smoke Special Inspection is required for the following items: N/A The following items are acceptable for deferred submittals: N/A GENERAL COMMENTS: Reviewed and accepted. ARCHITECTURAL COMMENTS: Sheets 3.1 and 3.2 Show fireplace location, hearth size, and materials. For factory built or zero clearance fireplaces, provide cut sheets, make, model number, and the approval number of the approved testing agency. Specifications are not required to be on plans. Factory built fireplaces shall comply with UL-127. For masonry fireplaces, show cross-section. Reference IRC Section R1003.1. COMMENT REMAINS: Not addressed. Sheet 4.2 For veneer, note and specify type of veneer. Provide detail and specify anchoring method, backing, vapor barrier, and support. Reference IRC Sections R301.2.2.3.1 and R703.7. COMMENT REMAINS: Not addressed. STRUCTURAL COMMENTS: Sheet 3.1 Provide stairway connection details and stringer sizes. Pre-fabricated metal stair shall have manufacturer’s specifications attached to plans. Reference IRC Section R106.1.1. COMMENT REMAINS: Not addressed. Sheet S2 Indicate the slope for exterior slabs. Reference IRC Section R311.6.1. COMMENT REMAINS: Not addressed. PLUMBING COMMENTS: Reviewed and accepted. MECHANICAL COMMENTS: Sheet M1.2 The exhaust fan schedule specifies three exhaust fans and on the floor plan four are indicated. Please clarify. Reference IRC Section 106.1.1. COMMENT REMAINS: Not addressed. ELECTRICAL COMMENTS: Sheet E3 Please provide cut sheets for all the exterior light fixtures shown or noted on Model plans. The cut sheets need to provide lumens per fixture and show if the fixture is a full cut-off, which means no light is emitted at or above the horizontal plane. For non-Model plans, please provide cut sheets and calculations for all exterior lighting fixtures. Reference the City of Tucson Outdoor Lighting Code. COMMENT REMAINS: Not addressed. Cross-reference exterior lighting fixtures on the plans with the cut sheets and calculations submitted. Reference the City of Tucson Submittal Requirements. COMMENT REMAINS: Not addressed. ENERGY CODE COMMENTS: Sheet M1.2 Annotate on the plans that any ductwork installed in unconditioned space will have a minimum of R-5 insulation, and any ductwork installed outside the building envelope will have a minimum of R-8 insulation. Reference IRC Section N1103.32. COMMENT REMAINS: Not addressed. ACCESSIBILITY COMMENTS: Reviewed and accepted. Sincerely, WILLDAN Martin Haeberle, C.B.O. Building Official MAH/tb |
12/20/2006 | ANDREW CONNOR | NPPO | REVIEW | Passed | |
12/28/2006 | GERRY KOZIOL | WWM | REVIEW | Denied | needs dsc 1st floor hold harmless letter for connection to an on-site private sewer #PT05S04298 which connects to a public sewer G-05-002 which has not been accepted & released by PCWWM |
12/29/2006 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | CDRC TRANSMITTAL FROM: Michael St.Paul, Planning Technician PROJECT: T06CM04893 879 West Paseo De Los Zonjeros PAD 10: Menlo Park, Mercado District, Lot 24 TRANSMITTAL: December 29, 2006 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. The plot plan as presented cannot be approved at this time. Please revise and resubmit the plot plan. 2. The legal description is "Menlo Park Mercado District Lot 24." Please place this on the site plan near the address. 3. The minimum setback for the garage to the edge of the private alley is three feet (Option A; p.35). Option A has already been established by Lots 27 through 30 across the alley. 4. Please be aware that there may be additional comments relative to changes in the plans submitted. |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
01/02/2007 | FSANCHE1 | OUT TO CUSTOMER | Completed |
01/02/2007 | SUE REEVES | REJECT SHELF | Completed |