Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T06CM04888
Parcel: 121120070

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T06CM04888
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/21/2006 GERRY KOZIOL WWM REVIEW Denied need 8th floor credit review
10/05/2006 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS for Activity # T06CM04888

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2003 International Residential Code, 2003 International Energy Conservation Code, and Arizona State amendments to the 2003 Uniform Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:

All corrections and revisions shall be made on original tracings or finished reproducible set. Return this set and a copy along with a set of the first submission. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets.

All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration.

Construction drawing guidelines are available from the residential desk of the Development Services Division.

As of 9-02-04 the City of Tucson has adopted the 2003 IRC with the exception of the plumbing portion which has been replaced with the 2003 UPC with amendments. All plans should reference these codes. See this site for all adopted amendments: http://www.tucsonaz.gov/dsd/Codes___Ordinances/Building_Codes/building_codes.html


Provide a note for: Underground facility tracer wires per DSD Memo, 10/24/2005.

SITE PLAN:

1. Show the water pipe size from the meter to the building. The pipe must be sized for the calculated load, 2003 UPC 610.1.

FOUNDATION PLANS:

1. Show or note a 6" minimum separation of untreated exterior posts above finished grade along with a 1" space above the floor, R319.1.4.
2. Show compliance with termite treatment specified by R320, as amended.
3. Note on the drawings the allowable soil bearing pressure used in the design of the footings, or state that the assumed value of 1500 PSF is being used per table R401.4.1 if a soils report is not provided.

FLOOR PLANS:

1. Show the kitchen window size (providing natural ventilation), R303.1.
2. Designate windows with tempered glass (within 24" of doorways), R308.4.
3. Note that tub/shower enclosures shall have nonabsorbent surfaces to 6' above the floor, R307.2. All glass enclosures shall be tempered, R308.4.5.
4. Show the location of a minimum 22"X30" attic access. Attic access is required if the space exceeds 30SF with a minimum of 30" of headroom, and shall be located in a hallway or readily accessible space, R807.
5. Locate and identify brace wall types and locations, R602.10.4 along with the appropriate tie-downs (wall segment with closet window) and nailing schedule, R602.10.8.

STRUCTURAL PLANS:

1. Provide complete roof framing plan. Show size and span of all headers consistent with Table 502.5(1)..
2. Show connections of all porch framing members including ledgers.
3. Specify lumber grade and species. Specify manufacturer and series on glue-lams and "I" joists.
4. Provide manufacturer's calculations and data for pre-fabricated trusses, R802.10.2, or note the requirement for deferred submittal approval prior to installation.
5. Specify the outrigger & gable end bracing and connections to the structure, R802.10.3.
6. Show lateral support of trusses. Show a detail of truss to wall connection using ties having a resistance to uplift of not less than 175 pounds, R802.10.5.

ELEVATIONS:

1. Indicate all wall materials used; wall board, stucco, siding, foam board, veneer, etc.
2. Note and specify a complete roofing system: Roofing type, grade of materials and method of installation, R905. Include porch roof.
3. Note and specify appropriate (two-layer) underlayment material for the low-slope (2:12 to 4:12) asphalt shingle roof, R905.2.7.
4. Show a minimum 2' termination above any roof point within 10' measured horizontally (not less than 3' above the point where the chimney passes through the roof), R1001.6.

SECTIONS - DETAILS - MISC. NOTES:

1. Clarify the inconsistent post base notation on pages 2 & 8.
2. Show wood framing members resting on concrete as pressure treated, R319.1(2).
3. Show the ceiling gypsum board as either 5/8" or ½" sag resistant when applied to 24" o/c framing, IRC table R702.3.5 footnote d.
4. Show weep screeds with a minimum clearance 4" above grade or 2" above paved areas, R703.6.2.1.
5. Calculate the attic ventilation area using the correct attic area in compliance with R806.2. Note only 80% of the required ventilating area may be provided by ridge or gable vents when applying the reduced area calculation. Show the amount of eave vents needed to comply.
6. Show a minimum 1" ventilation clearance between ceiling insulation and roof sheathing if insulation is attached to truss bottom cords and eave venting is used, R806.3. This may be accomplished w/ baffles.
7. Show chimney crickets, R1001.17.

PLUMBING PLANS:

1. The City of Tucson has adopted the 2003 Uniform Plumbing Code with state amendments (ARIZONA STATE PLUMBING CODE). The plans should reference this code.
2. Show a 1" water line between the two bathroom tees and the laundry sink tee, UPC 610.
3. Hose bibs require backflow preventers, UPC 603.
4. Provide pressure and temperature relief valve at water heater. T&P line must terminate at the exterior between 6 and 24 inches above grade and must terminate facing down, UPC 608.5.
5. Show the cleanout size (1-½" for drains up to 2" and 2-½" for drains up to 3") as required by Table 7-6. The water closet VTR may be used as the cleanout if increased to 2-½".
6. Show a two-way cleanout within 2' from the building at the lower end, UPC 707.4.

MECHANICAL PLANS:

1. Show bathroom exhaust fan minimum 50 CFM rating R303.3 and M1506.
2. Show the kitchen exhaust fan minimum 100 CFM rating, M1506.

ELECTRICAL PLANS:

1. Approval of an Overhead Service upgrade requires field verification. If used, a waiver request must be included with the permit application.
2. Provide equipment rated for 22,000 AIC short circuit protection, 2006 Edition of Electric Service Requirements TEP SR-510.
3. Note that light fixtures in clothes closets shall be installed in accordance with E3903.11.
4. Provide a note indicating only approved outlet boxes shall be used for ceiling fans, E4001.6.
R313.1.1.
5. Smoke alarms are required outside each separate sleeping area (hall at entry area) R313.1.2.

OUTDOOR LIGHTING CODE

1. The City of Tucson Outdoor Lighting Code requires compliance for both total lumen output (E3: 55,000 lumens per acre) and the unshielded component (E3: 12,000 lumens per acre). Show the exterior fixture wattage for determining lighting limits.
2. Full cut-off fixtures have no emittance above the nadir (fixtures are completely opaque above and to the lowest point of the lamp). Fixtures may be exempt from the total lumen budget if both of the full cut-off FCO style and located under overhangs, OLC 5.1.2. Provide cut sheets for all FCO fixtures showing the angle of cutoff, light emissions and fixture wattage. All other fixtures are assumed to be unshielded (non-FCO style).

INTERNATIONAL ENERGY CONSERVATION CODE:

1. Provide the simplified prescribed energy values for glazing U=0.65, ceiling R=30 and walls R=13 when glazing does not exceed 15% of exterior wall area, or provide energy calculations per the 2003 IECC w/ local amendments for compliance validations. If using REScheck select the climate zone 4B, Pima County < 4000 ft, 2100 HDD on the web version. http://www.energycodes.gov/rescheck/
2. Show the "R" values of insulation, as well as the "U" factors of the windows and doors on the plans as well as the solar heat gain coefficient SHGC minimum value of 0.40 rather than the previously accepted MEC values.

If you have any questions, please contact your assigned plans examiner Ken Van Karsen at 791-5550, extension 1112.

Final Status

Task End Date Reviewer's Name Type of Review Description
10/12/2006 CINDY AGUILAR OUT TO CUSTOMER Completed
10/12/2006 SUE REEVES REJECT SHELF Completed