Permit Number: T06CM04708
Parcel: 11704148A

Address:
647 N 9TH AV

Review Status: Completed

Review Details: SITE

Permit Number - T06CM04708
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/08/2007 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. According to BOA Case # C10-06-43 variances were granted for improvements indicated plans dated August 12, 2006 submit aforementioned plans for review and approval.

2. Indicate on the lower right hand corner of the site plan, the variance case number, and if applicable date of approval, and any conditions imposed.
01/08/2007 ANDREW CONNOR NPPO REVIEW Approved
01/29/2007 SUZANNE BOHNET ENGINEERING REVIEW Denied DATE: February 1, 2007
FROM: Suzanne Bohnet, CFM
Engineering Division

SUBJECT: 647 N. 9th Ave.
Glyph (restaurant)
Site Plan T06CM04708 (Third Review)

RESUBMITTAL REQUIRED: Site Plan.

The Site Plan cannot be approved as submitted. Please include a response letter to the comments below along with the corrected copies of the Site Plan with your next submittal.

Site Plan:
1. The dimension of sidewalks in the right-of-way is a minimum 5'. Please correct the Site Plan to reflect this.
2. A curb access ramp is required at the spot where the handicap-loading zone meets the curb, consistent with Standard Detail No. 207.
3. The provided curb access ramp at the corner of 4th St. and 9th Ave. cannot tie-in to the brick-paver sidewalk as shown. There is a ramp curb as shown on Standard Detail No. 207 (called out) that prevents this tie-in from providing unobstructed access. Either tie-in the sidewalk at a different spot(s) or submit a Development Standard Modification Request (DSMR) for the plan as shown.

Please do not hesitate to contact me with any questions.

Thank you,
Suzanne Bohnet, CFM
Engineering Associate
(520) 791-5550 x1188 office
Suzanne.Bohnet@tucsonaz.gov
03/01/2007 SREEVES1 ADA REVIEW Passed
12/22/2006 MARTIN BROWN FIRE REVIEW Approved
12/27/2006 KAROL ARAGONEZ ZONING HC SITE REVIEW Approved
12/27/2006 KAROL ARAGONEZ ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Karol Aragonez
Planner

PROJECT: T06CM04708
647 North 9th Avenue
Site Plan, 2nd Resubmittal

TRANSMITTAL DATE: December 27, 2006

COMMENTS:

1. Please add the Board of Adjustment case number C10-06-43 to all sheets of the site plan and landscape/irrigation plan. On sheet 2.0 add the variances that were granted and conditions of approval. Once corrections are made the site plan may be approved over the counter by zoning staff.


If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 1197.

S:\zoning review\planning\site review\T06cm04708r1.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan

Final Status

Task End Date Reviewer's Name Type of Review Description
04/04/2007 CINDY AGUILAR OUT TO CUSTOMER Completed
04/04/2007 SUE REEVES REJECT SHELF Completed