Permit Number: T06CM04708
Parcel: 11704148A

Address:
647 N 9TH AV

Review Status: Completed

Review Details: SITE

Permit Number - T06CM04708
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/23/2006 DAVE MANN FIRE REVIEW Approved
08/24/2006 ANDREW CONNOR NPPO REVIEW Denied Submit NPPO Application for Exception; include acceptable documentation, which clearly indicates that the project will not impact Protected Native Plants per DS 2-15.2.0.C.
08/24/2006 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. Submit a separate landscape plan per DS 2-07.0. to verify that entire site meets current minimum requirements.

2. A street landscape border, Sec. 3.7.2.4 of the LUC, is a landscape area with a minimum width of ten (10) feet, running the full length of the street property line bounding the site except for points of ingress-egress. Street landscape borders minimum width is 10 feet, and shall be located on site and measured from the street property line. Street landscape borders are required.

3. "There are situations where the LUC allows up to 5 feet of the required 10 feet of landscaping to be located within the right-of-way. The required landscaping may be located within the right-of-way only if there are no utilities within the same area, the required landscaping area is extended only to the back of sidewalk, and the City Engineer's Office approves such use in the right-of-way".

4. Fifty (50) percent or more of the street landscape border area must have shrubs and vegetative ground cover per LUC 3.7.2.4

5. Indicate square footage of all landscaped areas and calculation of the percentage of vegetative coverage per DS 2-07.2.2.2.g

6. One (1) canopy tree must be provided for every thirty-three (33) linear feet of landscape border per LUC 3.7.2.4.

7. The planting plan and layout calculations will include the following Information:

§ Both the proper and common name of each type of plant material must be listed.
§ Locations, size, and name of all existing vegetation to remain in place.
§ Material and areas of inert ground cover. All disturbed areas including adjacent right of ways shall be treated with ground cover such as decomposed granite to help reduce dust pollution per LUC 3.7.2.7. Indicate treatment for landscaped areas.

8. Within vehicular use areas, one (1) canopy tree is required for each 10 motor vehicle parking spaces and every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk) per LUC 3.7.2.3.A.1.a

9. Landscape plan shall include irrigation specification design and layout per DS 2-06.5.4.A & DS 2-06.5.4.B including source of irrigation, sleeves for driveways and sidewalks, locations of valves, low-flow bubblers or drip irrigation.

10. Submit NPPO Application for Exception; include acceptable documentation, which clearly indicates that the project will not impact Protected Native Plants per DS 2-15.2.0.C.

11. Include with re-submittal any variance documentation. Indicate on the lower right hand corner of the site plan, the variance case number, and if applicable date of approval, and any conditions imposed.
09/11/2006 SUZANNE BOHNET ENGINEERING REVIEW Denied To: Marlena Hanlon
DATE: September 11, 2006
FROM: Suzanne Bohnet, CFM
Engineering Division

SUBJECT: 647 N. 9th Ave.
Code Compliance for Change of Use
Site plan T06CM04708 (First Review)

RESUBMITTAL REQUIRED: Site Plan.

The Site Plan cannot be approved as submitted. Please include a response letter to the comments along with the corrected copies of the Site Plan with your next submittal.

Site Plan:
1. Please provide the sight visibility triangles (SVT) for the intersection of 9th Ave. and 4th St.

2. Please provide lot bearings and the Basis of Bearing.

3. Please provide the Basis of Elevation, including the vertical datum used.

4. Please provide street monument lines and the dimensions from street monument lines to existing curbs, sidewalks, driveways and utility lines.

5. Please provide the estimated cut and fill quantities, listed separately in measurements of cubic yards, even if the quantity is zero.

6. The Land Use Code (LUC) 3.7.4.3.B requires storm water harvesting for supplemental onsite irrigation purposes. Please provide water-harvesting techniques on your next submittal.

7. Please provide drainage flow arrows, with supporting spot elevations, to show drainage into the areas of water harvesting.

8. Please correct the orientation of the street parking stripes to reflect existing actual conditions.

9. Please provide a letter from the City of Tucson Dept. of Transportation (TDOT) that gives permission to use the right-of-way (ROW) for the proposed off-street parking stripes, the handicapped parking area, the concrete walkway, the bike parking and the loading zone.

10. Please provide more detail for refuse storage and collection. Per Development Standard (DS) 6-01.3.2.B, "Where the volume of refuse cannot be contained in three (3) garbage cans, each commercial establishment shall provide metal dumpster containers of adequate size." Show by calculation that the refuse generated by the business can be contained within 3 garbage cans for curbside pick-up by Environmental Services, and include this information on the Site Plan. Otherwise, please provide a dumpster with enclosure and collection vehicle access. Should you have any questions, please contact John Clark with the Environmental Services Dept. at (520) 791-3175.

If you have any questions, please do not hesitate to contact me.
Suzanne Bohnet, CFM, Engineer Associate
(520) 791-5550 x1188 office
Suzanne.Bohnet@tucsonaz.gov
09/13/2006 KAROL ARAGONEZ ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Karol Aragonez
Planner

PROJECT: T06CM04708
647 North 9th Avenue
Site

TRANSMITTAL DATE: September 13, 2006

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. It is not clear what the review is for whether this is for a change of use or expansion of structures or eating area. Please identify on the plan all existing structures including covered patios and outdoor eating space. Please provide a copy of the previously approved site plan for this site. Until information is provided full code review for the entire site will be done.

2. Please provide the bearings for all lot lines.
DS 2-02.2.1.A.5

3. It appears that on the 2002 photo aerials that a structure exists in the southeast corner of the lot. Please show all structures that exist on site, providing square footage, height, and setbacks for all.

4. Please add the square footage of the outdoor eating area and covered patios to the site area calculations.

5. All required motor vehicle parking spaces and maneuvering areas must be provided on site and meet the requirements of DS 3-05.0. Parking spaces located on street may not be counted toward required parking.
LUC 3.3.7.1.E.3 & DS 3-05.0

6. Please provide a typical for both standard and handicap off-street parking spaces. Details should be fully dimensioned, include wheel stop curbing if necessary, signage requirements for handicap parking, and access.
DS 2-02.2.1.A.8

7. The required number of parking spaces is based on the GFA of the building and outdoor eating area. Please clarify if the covered patio areas have been included in the outdoor eating area. If not the applicant should clarify if the covered patios are used for dining areas. If used for outdoor dining please provide the GFA of the covered patio area and include this in the calculations for motor vehicle and bicycle parking and off-street loading calculations. Please revise calculations accordingly.

8. All bicycle parking is to be provided on site. Per DS 2-09.0 figure 4 the type of bicycle rack being proposed by the applicant is considered an unacceptable design by not providing two points of support. Whereas figure 2 and 3 provide example of bike rack design that would be acceptable. Single racks are to provide a minimum of thirty (30) inches between the outer spaces of the posts of the rack. Please revise location to be placed on-site and revise the bicycle parking detail. Refer to figure 9 of DS 2-09.0.
DS 2-09.0

9. Please provide the location, type, size, and height of existing and proposed signage on the site plan.
DS 2-02.2.1.A.13

10. The proposed off-street loading space does not meet the requirements of LUC Sec. 3.4.0. All loading spaces shall be located on the same site or lot as the use they serve. The loading space shall be designed so that delivery trucks can be maneuvered in and out of the loading space based on national standards for turning radii. Please provide
DS 2-02.2.1.A.14, LUC 3.4.4.1 & LUC 3.4.4.2.C

11. All easements of record must be graphically shown on the plan together with recording docket and page reference. If none exists please state so in response.
DS 2-02.2.1.A.20

12. Please dimension the sidewalk area between planting areas to assure a minimum width of five (5) feet is maintained as a clear path.

13. Please dimension from the street monument lines to existing curbs, sidewalks, and utility lines. Label the width of curbing.
DS 2-02.2.1.A.21

14. Please show all existing and proposed lighting layouts if applicable.
DS 2-02.2.1.A.25

15. Please list the existing use of the property with the proposed use.
DS 2-02.2.1.A.31

16. Please add the size of the refuse container and indicate how access to the container is achieved to allow pick-up. Trash pick-up that varies from DS 6-01.0 will need to be approved by Environmental Services.
DS 2-02.2.1.A.32

17. Please provide gross and net lot area.
DS 2-02.2.2.A.1

18. Please provide in the notes the number of required and provided vehicle and bicycle parking spaces, including handicapped and required and provided off-street loading spaces
DS 2-02.2.2.A.4 & 5

19. Please provide the proposed FAR, building height, and setbacks listing them next to required. The required building setback from Fourth Street and Ninth Avenue is measured from property line, not back of curb. Please revise dimensions provided on site plan.
LUC 3.2.6.5.A

20. Please provide ramp at intersection of Fourth Street and Ninth Avenue. If one already exists please show it on the site plan. If the ramp is existing please make sure that truncated domes are installed as required. The following is criteria for accessible curb ramps per the 2003 ANSI.
Curb ramps or diagonal curb ramps shall be provided at all pedestrian crossings of vehicle use areas and streets where accessible routes are required. They shall be located so they do not project into vehicular traffic lanes, parking spaces, or parking access aisles. Ramps shall be located or protected to prevent their obstruction by parked vehicles.
ANSI 406
Curb ramps shall be a minimum of three (3) feet in width, exclusive of flared sides. The curb ramp flares shall not be steeper than 1:10. Counter slopes of adjoining gutters and road surfaces immediately adjacent to the curb ramp shall not be steeper than 1:20. The adjacent surfaces at transitions at curb ramps to walks, gutters and streets shall be at the same level.
ANSI 406.2, 3, & 4
All accessible curb ramps shall have truncated domes installed that shall be twenty-four (24) inches minimum in the direction of travel and extend the full width of the curb ramp or flush surface. The domes shall be located so the edge nearest the curb line is six (6) inches to eight (8) inches from the curb line.
ANSI 406.12, ANSI 705

21. Please note once changes, modifications, and/or corrections are made to the site plan resubmitted and reviewed, further comments may result.

If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550.

S:\zoning review\planning\site review\T06cm04708.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents
09/14/2006 KAROL ARAGONEZ ZONING HC SITE REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
10/24/2006 CINDY AGUILAR OUT TO CUSTOMER Completed
10/24/2006 SUE REEVES REJECT SHELF Completed