Permit Number: T06CM04676
Parcel: 133031130

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T06CM04676
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/04/2006 WILDAN 2ND PARTY REVIEW REVIEW Denied December 4, 2006

City of Tucson Development Services
201 N. Stone Avenue
Tucson, AZ 85701

RE: HIDDEN HILLS ADDITION – 2nd REVIEW
CITY OF TUCSON LOG NO. T06CM04676
WILLDAN PROJECT NO. 13881-6073

The second review for the above project has been completed. This letter contains comments which need to be addressed by written responses to each which indicate any actions taken. In order to facilitate a shorter third review, all corrections and revisions must be made on the original plans and two complete new sets of prints, along with one complete redlined set, must be returned to our office. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets, and that all changes have been highlighted with appropriate revision numbers, revision dates, and “cloud bubbles.” Pen or pencil corrections on final prints are not acceptable.

This project has been reviewed for conformance with the 2003 IRC, 1997 UAC, 2003 IMC, 2003 IECC, 2002 NEC codes with local modifications, and the 2003 UPC with State of Arizona Amendments. Any revisions to this plan will require an additional review and approval by Willdan.

Should you have questions regarding the comments herein, please contact your plans examiner Antonio Moya.

Occupancy Occup. Load Construction Area S.F. Sprinklered Alarms
R-3 13 V-B 2,554 No No


GENERAL COMMENTS:
Reviewed and accepted.

ARCHITECTURAL COMMENTS:
Reviewed and accepted.

STRUCTURAL COMMENTS:
Sheet 6
Note and specify all ledgers and connections to wood, frame, or masonry. Reference IRC Section R106.1.1. COMMENT REMAINS: Not addressed.

PLUMBING COMMENTS:
Sheet 8
Gas: Provide the length of the branch line to each appliance, BTU demand of each appliance, and size of each branch. Reference UPC Section 1217.2. COMMENT REMAINS: Not addressed.


MECHANICAL COMMENTS:
Reviewed and accepted.

ELECTRICAL COMMENTS:
Sheet 10
Note that at least one 20-amp branch circuit shall be installed to serve the laundry room and this circuit shall have no other outlets. Reference IRC Sections E3603.3, E3801.8. COMMENT REMAINS: Not addressed.

ENERGY CODE COMMENTS:
Reviewed and accepted.

ACCESSIBILITY COMMENTS:
N/A

Sincerely,

WILLDAN




Martin Haeberle, C.B.O.
Building Official

MAH/tb

Final Status

Task End Date Reviewer's Name Type of Review Description
12/05/2006 FSANCHE1 OUT TO CUSTOMER Completed