Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T06CM04479
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/25/2006 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved | |
| 09/25/2006 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | The corridor connecting the south and the east buildings is either a part of one of the adjacent buildings or it is an independent building. The corridor contains supply ductwork emanating from the south building which terminates within one foot of the east building. Assuming that the corridor is part of the south building, provide a 1-hour fire separation between the buildings. |
| 10/03/2006 | DOUG LAAKSO | BUILDING-COMMERCIAL | REVIEW | Denied | .. T06CM04479 .. (2701) EAST ELVIRA ROAD .. REMODEL OFFICE FOR UNIVERSITY PHYSICIANS HEALTHCARE .. DGL .. 2nd REVIEW .. 10/3/06 .. TRANSMIT PRIOR SUBMITTAL/S WITH NEXT SUBMITTAL. Provide a Response Letter, by the Registrant of Record, with the re-submittal addressing each comment listed in Structural Review. S1. Provide note on drawings addressing accessibility. See prior comment S5.( S5. Provide Project Cost for the Permit for this building and show on drawing G0.01 an estimate explaining where 20% of the Project Cost for this building is spent on accessibility or the building is brought into conformance with the 2003 IBC Section 11 and 34 and ANSI A117.1-2003 ed.) S2. See prior comment #S7. Show Accessible Route on Site Plan from public way through building/s and provide details as required to comply. (S7. . Detail on the drawings where conformance to the accessibility requirements of IBC Section 11 and 34 and ANSI A117.1-2003 ed are provided, showing how requirements are met and indicate Accessible Route.) S3. See prior comment #S8. Clarify allowable area calculation and define fully imaginary property lines per IBC Section 704. ( S8. Indicate, on drawings, the existing Occupancy and Type of Construction for existing buildings on site, per IBC Sections 3 and 6, respectively, also indicate the Location, Type of and Fire-rating of existing Fire Walls on site, explaining if and how they are or are not to be maintained for the purposes of this Permit, per IBC Section 7.) S4. See prior comment # S13. Please show this lighting on the electrical plan, if existing or provide it. (S13. Clarify how Means of Egress Illumination conforms to IBC Section 1006, ie: exterior exit lighting.) S5. See prior comment #S16. Use of 20 PSF Live Load for resisting Dead Loads such as mechanical equipment does not comply with IBC, revise response to comment #S16. ( S16. Provide Structural Calculations for : 1. Check existing roof structure capacity to support new ceiling, mechanical, electrical, fire sprinklers or other loads. 2. New canopy to replace existing at one location on this building.) Questions? Call Douglas Laakso Structural Plans Examiner for the City of Tucson Development Services Department at (520) 791-5550 x1111, email at <Doug.Laakso@tucsonaz.gov.> or visit City of Tucson , DSD website : www.tucsonaz.gov/dsd. |
| 10/04/2006 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Denied | TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL. PLEASE CALL AT 791-5550 X1106 OR EMAIL AT Linda.Buczynski@tucsonaz.gov IF YOU CARE TO DISCUSS. Approval pending the outcome of the review comment of the associated project on Activity Number T06CM04531. Electrical Plans Examiner has posted the following notice to the Electrical Inspector: "Verify ampacity of feeders to Panels A, B, C, D, & F." |
| 10/20/2006 | EGRANT1 | WWM | REVIEW | Needs Review |