Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE
Permit Number - T06CM04350
Review Name: RESUBMITTAL - SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/15/2007 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: Repair to 3520 E. Bermuda St. Apartments T06CM04350 Site Plan (3rd Review) TRANSMITTAL DATE: May 15, 2007 COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1 This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC). 2 This comment has not been fully addressed. The scale shown for the site plan and elevations does not meet the minimum text size. All lettering and dimension shall be the equivalent of twelve (0.12") point or greater in size. 3 This comment was not fully addressed. The majority of Unit #5 requires a permit. The hatching as shown does not show this. Revise plan to clearly show what is to be permitted. Clearly indicate on the plan what existing areas are to be permitted. 4 Zoning acknowledges that once all other comments are corrected that the following will require a Design Development Option (DDO). D.S. 2-02.2.1.A.7 per LUC Sec. 3.2.6.4 using a development designator of "K" with a perimeter yard indicator of "BB" the required side and rear yard setback to a R2 zoned property is ten (10) feet or ¾ (H) the hieght of the proposed building wall, which ever is greatest. Based on the provided elevations the required setback to all side and rear yard property lines would be ten (10) feet. This said: a. The required setback from unit 5 to the west property line should be 10'-0". A D.D.O is required for the provided setback of 9'-0". b. The required setback from the pop out on unit 7 to the south property line should be 10'-0". A D.D.O is required for the provided setback of 6'-10". c. The required setback from the pop out on unit 4 to the east property line should be 10'-0". A D.D.O is required for the provided setback of 3'-6". 5 The Design Development Option (DDO) may not be applied for until all requested changes have been provided on the plan and have been reviewed by zoning. 6 Additional comments may be forth coming depending on how each comment has been addressed. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 791-5608 ext. 1180. C:\planning\site\t07cm00295-3rd.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/18/2007 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 05/18/2007 | DELMA ROBEY | REJECT SHELF | Completed |