Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T06CM04243
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/07/2006 | LINHART PETERSEN POERS ASSOC. | 2ND PARTY REVIEW | REVIEW | Denied | November 3, 2006 CITY OF TUCSON - SECOND CHECK Tucson Appl. No. T06CM04243 Bureau Veritas Job No. 01006-161039 Mr. Troy Williams 4561 W. Annabell St Tucson, AZ 85741 Re: Plan Review: Williams Residence Address: 4965 S. 13th Ave Bureau Veritas, has completed a second review of the following documents on behalf of the City of Tucson: 1. Plans: One (1) set of plans (14 sheets, 1 through 12) no dates or stamps. 2. Structural Calculations: None submitted. Energy Code Compliance: None submitted. Miscellaneous Documents: None submitted. These documents were reviewed only for their conformance to the provisions of the 2003 International Building Codes (i.e., State of Arizona and Tucson amended 2003 IRC, 2003 IMC, 2002 NEC and 2003 IPC). Please submit an itemized response letter and required number of complete and revised documents with all revisions clouded. Sincerely, Bureau Veritas Randy McCoy ICC Plans Examiner RM:pc c:/tucson\01006-161039pc2 enclosures Re: Stories: One Occupancy R-3 Fire Sprinklers: No Building Area (sq. ft.): 3600 (livable) 1072 (porch) 4672 Total A. The following plan review comments are based on the City of Tucson Building Regulations and referred to the 2003 International Residential Code. B. Please respond in writing to each comment by marking the attached comment list or creating a response letter. Indicate which detail, specification, or calculation shows the requested information. Your complete and clear responses will expedite the re-check and hopefully, approval of this project. Thank you for your assistance. These plan review comments are based on building code items only. If site-related comments are applicable to this project, they will be generated by others (e.g., County Engineering, Public Works, Health, etc.). Truss Systems: Trusses can be submitted as a “Deferred Submittal” for custom homes only. However, they must be submitted and approved prior to their fabrication. Provide complete truss calculations and truss layout plan. Truss designs submitted must include all types and be designed for the loading conditions, span, slope, and spacing designated on the framing plan. Truss calculations must be signed, dated and sealed by an Engineer who is registered in the State of Arizona. The seal on the truss calculations shall be dated within the latest adopted IRC. Specify all hangers used to hang trusses from girder trusses, walls, or other locations. IRC Sec. R802 & ANSI-TPI 1995. The architect and engineer of record must review truss calculations (when applicable). Truss calculations must bear a shop drawing stamp showing this review has been done. MECHANICAL: The clothes dryer exhaust duct shall be at least the diameter of the appliance outlet and shall terminate on the outside of the building. It shall not exceed 25 feet in length with reductions for bends. The duct shall terminate not less than 3 feet from a property line. IRC Sec. M1501 and R302.2. Show condensate line and secondary condensate line. IRC Sec. M1411.3 and M1411.3.1. ELECTRICAL: Receptacle outlets for ranges and clothes dryers shall be a 3-pole with ground type. Four-wire, grounding-type flexible cords will be required for connection of ranges and clothes dryers. The bonding jumper shall not be connected between the neutral terminal and the frame of the appliance. IRC Section E3808. If you have any questions regarding the above comments, please contact Randy McCoy at (520) 576-8400 between 8:00 A.M. to 5:00 P.M., M-F. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/07/2006 | SUE REEVES | OUT TO CUSTOMER | Completed |